36-75 Vdc Input; 1.2 Vdc to 5 Vdc Output; 6.6A to 12A

HW006/010/012 Series Power Modules; dc-dc Converters

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress
ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the
operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the
device reliabiltiy.

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.

CAUTION: This power module is not internally fused. An input line fuse must always be used.

This power module can be used in a wide variety of applications, ranging from simple stand-alone operation to an integrated
part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included however, to achieve
maximum safety and system protection, always use an input line fuse. The safety agencies require a time-delay fuse with a
maximum rating of 5 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush
energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s
data sheet for further information.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage:Continuous

Transient (100ms)

HW
HW

VI

VI, trans

–0.3

80

100

Vdc
Vdc

Operating Ambient Temperature
(See Thermal Considerations section)

All

TA

–40

85

°C

Storage Temperature

All

Tstg

–55

125

°C

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage

HW

VIN

36

48

75

Vdc

Maximum Input Current
(VI = 0 V to 75 V; IO = IO, max)

HW

II, max

1.6

Adc

Inrush Transient

All

I

2

t

1

A

2

s

Input Reflected Ripple Current, peak-peak
(5 Hz to 20 MHz, 12 µH source impedance
See Test configuration section)

All

II

3

mAp-p

Input Ripple Rejection (120 Hz)

All

50

dB