background image

REMOVAL OF THE TEMPORARY

RESTORATION AND CLEANING

CLEANING AND TREATMENT

OF THE RESTORATION

FOR BONDING

CEMENTATION

Remove temporary restoration, sealing material or cement. Clean cavity. Rinse and
dry cavity thoroughly.

Internal Metal bonding surface

Sandblast the metal surface with aluminum oxide (+/- 50 microns) and apply a
thin layer of GC METALPRIMER II. After applying the primer, carefully avoid
contaminating the metal surface before cementing the restoration.

Precaution: Apply one or two thin coats of GC METALPRIMER II. A too thick coat

can reduce adhesive strength.


GC GRADIA internal bonding surface (metal free restorations)

Apply thin layer of GC COMPOSITE PRIMER to internal bonding surface then light
cure with conventional operatory curing light for 20 sec.
When using LABOLIGHT LV-II/LV-III, light-cure for one minute.

Adjust occlusal surface with diamond or carborundum point then use silicone
points. Finally, add GC GRADIA DIAPOLISHER to felt or chamois wheel and buff
to a lustrous finish.

GC METALPRIMER II

GC COMPOSITE
PRIMER

GC LABOLIGHT LV-II / LV-III

GC GRADIA DIAPOLISHER

ADJUSTING & POLISHING

OCCLUSAL SURFACE

11

GC FUJI PLUS

Cement with GC FUJI PLUS or comparable dental cement per
manufacturer’s instructions.