Composite build-up procedure, Anterior veneer crown (incisal free metal backing) – GC EUROPE GRADIA User Manual

Page 14

Advertising
background image

EI1

E3

DA3

CT2

ODA3.5

MO

FO

OA3

1mm

1. PREPARING MASTER MODEL

2. WAX-UP

Prepare the master model in the
usual manner using GC Fujirock EP.
Margins pencilled in red.

Underlying wax colour acts as a depth
guide.

Scribe 1 mm from incisal and proximal
areas, establishing where metal
casting limits will be. Using a wax
bur or instrument, remove 1 mm
depth of wax incisal/lingual.

Use GC Exaflex Putty for making a
silicon impression index.

Remove excess of silicon incisally to
an angle of 45°. This silicon index
is later used in building up Dentin
and Enamel.

4.MAKING CASTINGS

Wax up die with GC Inlay Wax.

Retention Beads II SSS (particle
size: 100μ) enhance mechanical
bond strength between casting and
GC GRADIA composite veneer.
Used in combination with
GC Metalprimer II bonding agent.

Apply a thin layer of Adhesive II for

GC Retention Beads II SSS.

Let surface dry and become tacky.

Sprinkle a layer of GC Retention
Beads II SSS evenly over wax
surface.

Sprue and invest using a GC
phosphate bonded investment and
cast in a normal way.

5. COMPOSITE BUILD-UP PROCEDURE

12

Apply GC Multisep to the master die.
Use different coloured wax in order
to easily identify the thickness of wax
during veneer cut-out.
Fully contour the wax-up.

Metal

45°

Make lingual silicone impression
index.

3. PREPARE SILICONE INDEX

Silicone
index

Wax-up

1. ANTERIOR VENEER CROWN (INCISAL FREE METAL BACKING)

Advertising