CLI command : l2 vlan create <vlan id> <vlan name> <port list>

CLI command : l2 vlan add <vlan id> <port list>

CLI command : l2 vlan remove <vlan id> <port list>

CLI command : l2 vlan utportadd <vlan id> <untagged port list>

[Remove VLAN]

Allows user to completely destroy an existing VLAN.

CLI command : l2 vlan delete <vlan id>

[Reload]

Restores the previous saved settings from configuration file.

CLI command : l2 vlan retrieve

[Show Port]

Displays the port configuration

CLI command : l2 port show <port id or * for all ports>

[PVID]

Sets the default VLAN for a port by giving a VLAN ID and its associated port
member list.

CLI command : l2 port vlan <vlan id, 4095 to disable the port-based
vlan> <port list>

[CoS Value]

Sets the Class of Service for a port by assigning it a priority (with range of 0-7)
criteria value for untagged packets. Due to 4 internal traffic class mapping to 8
priority, 4 Cos value (ex. 0,2,5,7 for default queue mapping) are valid
according to Cos Queue Mapping.

CLI command : l2 port priority <CoS> <port list>