Hardware setup, 13 scsi id setting – Asus AP2300 User Manual

Page 33

Advertising
background image

33

4. Hardware Setup

4. Hardware Setup

AP2300 Hardware Reference Guide

SCSI ID settings are made through DIP switches located on the SCSI
backplane board. The SCSI backplane board has 6 DIP switches to set the
hard drive’s power-ON delay and SCSI ID.

• 4-13 SCSI ID Setting

SCSI ID Setting

1 2 3 4 5 6

O

N

Default Settings

SCSI ID#s are determined by the host – A SCSI hard
drive mounted in a hot-swap “tray” will not have a SCSI
“ID” until it is inserted into a hot-swap “bay”.

1 2 3 4 5 6

O

N

Resulting SCSI ID#s
Top Bay

ID

Tray5

12

Tray4

08

Tray3

04

Tray2

02

Tray1

00

Bottom Bay

Switch 5 OFF

Switch 5 ON

Resulting SCSI ID#s
Top Bay

ID

Tray5

13

Tray4

09

Tray3

05

Tray2

03

Tray1

01

Bottom Bay

1 2 3 4 5 6

O

N

Delay HD motor spin-up (12 x SCSI ID in milliseconds) (ON)
Remote HD motor spin-up initiated (OFF)
Bay SCSI ID Setting (see below)

Reserved

Reserved

All SCSI devices must have a SCSI identification number that is not in
use by any other SCSI device. SCSI devices vary in how they set the
ID number. Refer to the product manual for any additional devices that
you may install for details on how to set its ID number.

NOTE

Advertising