TABLE 2-3. MECHANICAL DATA
ITEM
CHARACTERISTICS
Shipping and Storage Case
Size: Approx. 356 x 241 x 203 mm (14” x 9.5” x 8”)
Weight: 1.09kg (2.4 lbs.)
Carrying Case
Size: Approx. 352 x 240 x 200 mm (14” x 9.5” x 8”)
Monocular (see Note)
Weight: 0.39kg (14 ounces)
NOTE:
The weight of the monocular does not include accessories.
TABLE 2-4. OPTICAL DATA
ITEM
DATA
Magnification
1.0X (3X with 3X magnifier)
Field-of-View
40° (13° with 3X magnifier)
Diopter Focus
+2 to -6 diopters
Objective Focus
25cm (9.8”) to infinity
TABLE 2-5. ENVIRONMENTAL DATA
ITEM
DATA
Monocular Operating Temperature
-51°C to +49°C
Monocular Storage Temperature
-51°C to +85°C
Illumination Required
Overcast starlight to moonlight
2.3 PRINCIPLES OF OPERATION
2.3.1. MECHANICAL FUNCTIONS
The mechanical functions used to operate the NVMPS adjust to accommodate physical differences of
individual operators. These functions include the power switch, eye relief adjustment, diopter adjust-
ment, gain control, and objective focus. The mechanical controls are identified in Figure 2-4.
NOTE:
The gain control function is not available with the 6015 or PVS-14NG model.
2.3.2 OPTICAL FUNCTIONS
The optical functions include an objective lens, image intensifier, and eyepiece lens (Figure 2-6). The
objective lens collects light reflected from the environment. The image is inverted and focused on the
image intensifier. The image intensifier converts the captured light into a visible image, re-inverting it
so that it can be viewed through the eyepiece lens.