Electronic circuit function, A. power source, B. high light cut-off – Armasight NAM601500126DH1 PVS14/6015 GEN 2+ HD Multi-Purpose Night Vision Monocular User Manual

Page 17

Advertising
background image

17

2.3.3. ELECTRONIC CIRCUIT FUNCTION

The electronic circuit regulates the direct current voltage from the battery to the image intensifier and

IR source as required. It also monitors the output voltage of the battery and turns on a low-battery

indicator when the available battery voltage is 1.9 – 2.1 Vdc.

a. Power Source

The electronic circuit is powered by one battery.

b. High Light Cut-Off

The monocular will automatically turn off after 70 ±30 seconds of operation in daylight or other bright-

ly lit environments. Individual bright lights (headlights, flashlights, or other concentrated light sources)

will not actuate the high light detector located on the front of the monocular. To turn the monocular

back ON, turn the power switch to RESET/ OFF, and then to ON again.

PHOTOCATHODE

MICROCHANNEL

PLATE

FIBER-OPTIC

INVERTER

OBJECTIVE

LENS

PHOSPHOR

SCREEN

IMAGE

INTENSIFIER

POWER

SUPPLY

EYEPIECE

LENS

EYE

Figure 2-6. Optical Function Diagram

Advertising