AVSL Citronic CLA-1460 User Manual

Page 5

Advertising
background image

171.220 User Manual

Installation

Single Flown Array

For standard single flown array, installation is executed using 4 eyebolts attached to each corner of
the flying frame. Fixings should be the strongest possible type for the substrate or ceiling supports to

ensure a fail-safe installation. Suspension via wire rope or steel cables, each with a breaking strain of
no less than 400kg is recommended per single line-array system.
In some situations, it may be easier to suspend the sub unit first and then assemble line-array

speakers below it, ensuring that the weight of each is adequately supported before securing to the
array.


















Once assembled, the line-array can be curved to address the listening field by selecting various angle
points on the rear angle adjustment brackets provided. The angle chosen depends largely upon the

distance from the audience and the acoustic environment but should be adjusted so that each array
speaker unit is vertically focused to evenly distribute the output across the listening field.

Each Passive Back Link bracket has numbered lines for tilt in degrees. Whilst supporting the weight

of the passive speaker, use these lines to align the correct fastening hole for the degree of tilt
required for each component in the array.