Thermal Resistance


Symbol Parameter

Rating Unit

TSOT25 V-DFN3030-6

θ

JA

Junction to Ambient

82

44

°C/W

Ψ

JB

Junction to Board

33

°C/W

θ

JC

Junction to Case

14

°C/W



Recommended Operating Conditions

(@T

A

= +25°C, unless otherwise specified.)


Symbol Parameter

Min

Max

Units

V

IN

Input voltage (Note 4)

6

60

V

t

OFFMIN

Minimum switch off-time

800

ns

t

ONMIN

Minimum switch on-time

800

ns

f

LX max

Recommended maximum operating frequency (Note 5)

625

kHz

D

LX

Duty cycle range

0.01

0.99

T

OP

Operating temperature range

-40

+125

°C

Notes: 4.

V

IN

> 16V to fully enhance output transistor. Otherwise out current must be derated - see graphs. Operation at low supply may cause excessive heating

due to increased on-resistance. Tested at 7V guaranteed for 6V by design.

5. ZXLD1356 will operate at higher frequencies but accuracy will be affected due to propagation delays.