Electrical characteristics, Zmt32 – Diodes ZMT32 User Manual

Page 3

Advertising
background image

ZMT32

Issue 1 - June 2008

3

www.zetex.com

© Zetex Semiconductors plc 2008

Electrical characteristics

General test conditions (unless otherwise noted)

T

A

= +23

±5

o

C, V

CC1

=V

CC2

= +5V, H

ROT

=25kA/m

(†)

, k=100•(V

PO1

/V

PO2

) with V

CC1

=V

CC2

A: Output characteristic definitions

∆V

O1

/V

CC1

= (V

OMAX1

– V

OMIN1

)/V

CC1

or/ ∆V

O2

/V

CC2

= (V

OMAX2

– V

OMIN2

)/V

CC2

V

OFF1

/V

CC1

= ½(V

OMAX1

+ V

OMIN1

)/V

CC1

or/ V

OFF2

/V

CC2

= ½(V

OMAX2

+ V

OMIN2

)/V

CC2

∆αH = MAX | α

LEFT TURN

– α

RIGHT TURN

| (max. angular difference between left and right turn)

∆α = MAX | α

o

– α |

(max. angular difference between actual value α

o

and measured angle,

without offset error)

B: Temperature coefficient (TC) equations

T

1

= -25°C,

T

0

= +25°C,

T

2

= +125°C

where

is the peak-peak output voltage at

temperature T

n

SYMBOL

PARAMETER

CONDITIONS

MIN

TYP

(*)

NOTES:

(*) Typical values apply to an ambient temperature of 23

o

C

MAX

UNIT

S

α1

or S

α2

Sensitivities (zero crossing)

α1=135°, α2=0°

0.35

mV/V/deg

V

PO1

or V

PO2

Peak Output Voltages
(sinusoidal signals)

40

50

60

mV

k

Amplitude bridge matching

99.77

100

100.23

%

TCk

Temperature coefficient of
amplitude bridge matching

T

A

= -40 to +160°C

-0.008

+0.008

%/K

R

B1

or

R

B2

Bridge resistances

no H

ROT

T

A

= -40°C

2017

3040

Ω

T

A

= 23°C

2500

3000

3600

T

A

= +160°C

3345

5114

TCR

B

B

TC of Bridge Resistances

+0.28

+0.32

+0.36

%/K

∆V

O1

/V

CC1

A

or

∆V

O2

/V

CC2

A

Peak to peak output swing

T

A

= -40°C

19.2

30.4

mV/V

T

A

= 23°C

16

20

24

T

A

= +160°C

6.7

13.4

H

ROT

= 8 kA/m

(†)

T

A

= 23°C

16

20

24

TCV

O

B

TC of peak to peak output
swing

-0.35

-0.32

-0.28

%/K

V

OFF1

/V

CC1

A

or

V

OFF2

/V

CC2

A

Output offset voltage

T

A

= -40°C

-1.25

+1.25

mV/V

T

A

= +160°C

-1.55

+1.55

H

ROT

= 8 kA/m

(†)

(†) See point “Magnetic Field Tests” below

T

A

= 23°C

-1

0

+1

no H

ROT

-2

0

+2

TCV

OFF

B

TC of output offset voltage

-4

0

+4

µV/V/K

∆α

A

Angular Inaccuracy

0.05

0.2

deg

∆αH

A

Angular hysteresis

0.1

deg

H

ROT

= 8 kA/m

(†)

0.5

(‡)

(‡) The accurate control of this parameter (Lim

max

=0.1deg, H

ROT

=25kA/m) takes place by means of sample tests

deg

I

iso1-2

Isolation Bridge Current

no H

ROT

0

0.1

µA

%

100

)

T

(

V

V

)

T

(

V

V

)

T

(

V

V

T

T

1

TCV

0

CC

O

1

CC

O

2

CC

O

1

2

O

×

Δ

Δ

Δ

×

=

)

T

(

V

V

n

CC

O

Δ

Advertising