Ap5002, Electrical characteristics, Pwm control 2a step-down converter – Diodes AP5002 User Manual

Page 4

Advertising
background image

AP5002

PWM CONTROL 2A STEP-DOWN CONVERTER

AP5002 Rev. 8

4 of 10

FEBRUARY 2009

www.diodes.com

©

Diodes Incorporated

Electrical Characteristics

(V

IN

= 12V, T

A

= 25

°

C, unless otherwise specified)


Symbol

Parameter

Conditions

Min

Typ.

Max

Unit

V

FB

Feedback

Voltage

I

OUT

= 0.1A

0.784

0.8

0.816

V

I

FB

Feedback

Bias

Current I

OUT

= 0.1A

-

0.1

0.5

µA

I

CCQ

Quiescent

Current

V

FB

= 1.2 force drive off

-

3

5

mA

I

SW

Switch

Current

--

3.5

-

-

A

I

SD

Shutdown

Supply

Current V

EN

= 0V

-

10

-

µA

∆V

OUT

/V

OUT

Line Regulation

V

IN

= 4V~20V, I

OUT

= 0.2A

-

1

2

%

∆V

OUT

/V

OUT

Load Regulation

I

OUT

= 0.1 to 2A

-

0.5

1

%

f

OSC

Oscillation

Frequency

Measure

waveform at SW pin

400

500

600

KHz

V

SH

EN Pin Input Voltage

Evaluate oscillation at SW pin

2.0

-

-

V

V

SL

Evaluate oscillation stop at SW pin

-

-

0.8

I

SH

EN Pin Input Leakage
Current

Ven = 2V

-10

-

10

µA

I

SL

Ven

=

0.8V

-10

-

10

µA

T

SS

Soft-Start

Time

--

- 3 -

ms

R

DSON

Internal MOSFET Rdson

V

IN

= 5V, V

FB

= 0V

-

110

150

m

V

IN

= 12V, V

FB

= 0V

-

70

100

Thermal shutdown

140

o

C

Minimum Duty Cycle

6.5

%

θ

JA

Thermal Resistance
Junction-to-Ambient

SOP-8L (Note 3)

124

o

C/W

θ

JC

Thermal Resistance

Junction-to-Case

SOP-8L (Note 3)

25

o

C/W

Notes: 3. Test condition: Device mounted on 2oz copper, minimum recommended pad layout, FR-4 PCB.























Advertising