Ap6015, Recommended operating conditions, Electrical characteristics – Diodes AP6015 User Manual

Page 4

Advertising
background image

AP6015

High Efficiency Step-Down Low Power DC-DC Converter

AP6015 Rev. 3

4 of 18

FEBRUARY 2009

www.diodes.com

©

Diodes Incorporated

Recommended Operating Conditions

(T

A

:-40~85

°C)


Symbol

Parameter

Rating

Unit

T

A

Operating Ambient Temperature Range

-40 to +85

o

C

V

IN

Supply Voltage

2.0 to 5.5

V

V

O

Output voltage range for adjustable output voltage version

0.8 to V

I

V

L

Inductor (see Note 4)

3.3

μH

C

i

Input capacitor (see Note 4)

10

μF

C

o

Output capacitor (see Note 4) V

O

≥ 1.8V

10

μF

Notes: 4. Refer to application section for further information.


Electrical Characteristics

(T

A

=25

°C)


Over recommended operating free-air temperature range, V

I

=3.6V, V

O

=2.5V, I

O

=300mA, EN=V

IN

. (unless otherwise noted)

Symbol

Parameter

Conditions

Min

Typ.

Max

Unit

Supply current

V

IN

Input

Voltage

range

-20 to 85

o

C

I

O

= 0mA to 800mA

2.5

-

5.5

V

I

O

= 0mA to 500mA

2

-

5.5

-40 to 85

o

C

I

O

= 0mA to 600mA

2.5

5.5

I

O

= 0mA to 400mA

2

-

-

Iccq

Operating quiescent current

I

O

= 0mA

-

150

-

μA

I

STBY

Standby

current

EN=

GND

- 0.1 1

μA

Enable

V

IH

EN high-level input voltage

V

IN

≤ 3V

1.5

-

-

V

V

IN

> 3V

2.5

-

-

V

IL

EN low-level input voltage

-

-

0.7

V

I

L

EN input leakage current

EN= GND or V

IN

-

0.01

0.1

μA

V

(UVLO)

Under-voltage-lockout-threshold

1.2 1.6 1.95

V