AP2182/ AP2192

Document number: DS31569 Rev. 7 - 2

3 of 17

www.diodes.com

April 2013

© Diodes Incorporated

AP2182/ AP2192



Absolute Maximum Ratings

(@T

A

= +25°C, unless otherwise specified.)

Symbol Parameter Rating

Unit

ESD HBM

Human Body Model ESD Protection

3

kV

ESD MM

Machine Model ESD Protection

300

V

V

IN

Input Voltage

6.5

V

V

OUT

Output Voltage

V

IN

+0.3

V

V

EN ,

V

FLG

Enable Voltage

6.5

V

I

LOAD

Maximum Continuous Load Current

Internal Limited

A

T

J(MAX)

Maximum Junction Temperature

150

°C

T

ST

Storage Temperature Range (Note 4)

-65 to +150

°C

Caution: Stresses greater than the 'Absolute Maximum Ratings' specified above, may cause permanent damage to the device. These are stress ratings only;

functional operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may be
affected by exposure to absolute maximum rating conditions for extended periods of time.

Semiconductor devices are ESD sensitive and may be damaged by exposure to ESD events. Suitable ESD precautions should be taken when handling

and transporting these devices

Note:

4. UL Recognized Rating from -30°C to +70°C (Diodes qualified

T

ST

from -65°C to +150°C)


Recommended Operating Conditions

(@T

A

= +25°C, unless otherwise specified.)

Symbol Parameter Min

Max

Units

V

IN

Input voltage

2.7

5.5

V

I

OUT

Output Current

0

1.5

A

V

IL

EN Input Logic Low Voltage

0

0.8

V

V

IH

EN Input Logic High Voltage

2

V

IN

V

T

A

Operating Ambient Temperature

-40

+85

C