Absolute maximum ratings, Recommended operating conditions, Electrical characteristics – Diodes AH1809 User Manual

Page 3: Ah1809

Advertising
background image

AH1809

Document number: DS35523 Rev. 3 - 2

3 of 13

www.diodes.com

February 2014

© Diodes Incorporated

AH1809

Absolute Maximum Ratings

(Note 6) (@T

A

= +25°C, unless otherwise specified.)

Symbol Parameter

Rating

Unit

V

DD

Supply Voltage (Note 7)

7 V

V

OUT

Output Pin Voltage (Note 7)

7

V

V

DD REV

Reverse Supply Voltage

-0.3

V

V

OUT_REV

Reverse Output Pin Voltage

-0.3

V

I

OUTPUT

Output current (source and sink)

2.5

mA

B

Magnetic Flux Density

Unlimited

P

D

Package Power Dissipation

SC59 and SOT553

230

mW

SIP-3L 230

Ts

Storage Temperature Range

-65 to +150

°C

T

J

Maximum Junction Temperature

+150

°C

ESD HBM

Human Body Model ESD capability

6

kV

Notes:

6. Stresses greater than the 'Absolute Maximum Ratings' specified above may cause permanent damage to the device. These are stress ratings only;

functional operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may be

affected by exposure to absolute maximum rating conditions for extended periods of time.

7. The absolute maximum V

DD

of 7V is a transient stress rating and is not meant as a functional operating condition. It is not recommended to

operate the device at the absolute maximum rated conditions for any period of time.


Recommended Operating Conditions

(@T

A

= +25°C, unless otherwise specified.)

Symbol Parameter

Conditions

Rating

Unit

V

DD

Supply Voltage

Operating

2.5 to 5.5

V

V

OUT_MAX

Maximum output pin voltage

Operating

5.5

V

T

A

Operating Temperature Range

Operating

-40 to +125

°C



Electrical Characteristics

(@T

A

= +25°C, VDD = 3V, unless otherwise specified.)

Symbol Parameter

Conditions

Min

Typ

Max

Unit

V

OUT_ON

Output On Voltage (V

OL

)

I

OUT

= 1mA

— 0.1 0.3 V

Ioff Output

Leakage

Current

V

OUT

= 5.5V, Output off

< 0.1

1

µA

I

DD

(awake)

Supply Current

During ‘awake’ period,
T

A

= +25°C, V

DD

= 3V

3

6

mA

During ‘awake’ period,
T

A

= -40 to +125°C, V

DD

= 2.5V to 5.5V

— 12 mA

I

DD

(sleep)

During ‘sleep’ period,
T

A

= +25°C, V

DD

= 3V

5 10 µA

I

DD

(sleep)

During ‘sleep’ period,
T

A

= -40 to +125°C, V

DD

= 2.5V to 5.5V

28

µA

I

DD

(avg)

Average Supply Current

T

A

= +25°C, V

DD

= 3V

8 16 µA

T

A

= -40 to +125°C, V

DD

= 2.5V to 5.5V

— 40 µA

Tawake Awake

Time

(Note

8)

75 125 µs

Tperiod Period

(Note

8)

75 125 ms

D.C. Duty

Cycle

0.1 — %

Note:

8. When power is initially turned on, the operating V

DD

must be within its correct operating range (2.5V to 5.5V) to guaranteed the output sampling.

The output state is valid after the second operating cycle (typical 150ms).

Advertising