Application Note

Applications Circuit One – Low Band

Connecting the BSEL pin to ground permanently configures the AH1898 into its high sensitivity mode, requiring a reduced magnetic flux density
to activate its output (Low Band).



Applications Circuit Two – High Band

Connecting the BSEL pin to V

DD

or to a voltage greater than 1.4V or leaving the BSEL pin unconnected configures the AH1898 into its low

sensitivity mode, requiring a higher magnetic flux density to activate its output (High Band).


Applications Circuit Three – Adjustable Sensitivity

To enhance flexibility within the application, the sensitivity can be adjusted with a standard logic signal allowing it to be controlled by a micro-
controller or a logic source. This allows the sensitivity to be changed within the application without a hardware change. Whenever the sensitivity
band selection is changed, the band selection changeover should be allowed to complete for the output to be valid.