Data sheet, Absolute maximum ratings (t, Recommended operating conditions – Diodes AH9249 User Manual

Page 4: Parameter symbol min max unit

Advertising
background image


Data Sheet

High Sensitivity Micropower Omnipolar Hall-Effect Switch AH9249

Jul. 2011 Rev. 1. 6 BCD Semiconductor Manufacturing Limited

4

Absolute Maximum Ratings (T

A

=25

°C, Note 1)

Parameter Symbol

Value

Unit

Supply Voltage

V

CC

7 V

Supply Current (Fault)

I

CC

6 mA

Output Voltage

V

OUT

7 V

Output Current

I

OUT

2 mA

Magnetic Flux Density

B

Unlimited

Gauss

TO-92S-3 400

SOT-23-3 230

Power Dissipation

P

D

DFN-2×2-3 230

mW

Storage Temperature

T

STG

-55 to 150

Junction Temperature

T

J

150

°C

ESD (Human Body Model) (Note 2)

4000

ESD (Machine Model) (Note 2)

600

V

Note 1: Stresses greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to
the device. These are stress ratings only, and functional operation of the device at these or any other conditions
beyond those indicated under “Recommended Operating Conditions” is not implied. Exposure to “Absolute
Maximum Ratings” for extended periods may affect device reliability.
Note 2: Electronic semiconductor products are sensitive to Electro Static Discharge (ESD). Always observe
Electro Static Discharge control procedures whenever handling semiconductor products.



Recommended Operating Conditions

Parameter

Symbol Min

Max Unit

Supply Voltage

V

CC

2.5

5.5

V

Operating Temperature

T

OP

-40

85

°C