background image

APX4558

DUAL CHANNEL LOW NOISE GENERAL PURPOSE

OPERATIONAL AMPLIFIER

APX4558

Document number: DS35022 Rev. 4 - 2

2 of 10

www.diodes.com

January 2011

© Diodes Incorporated

NEW PROD

UC

T

Pin Descriptions

Pin #

Name

Description

1 1OUT

Amplifier

1

output

2

1IN-

Amplifier 1 inverting input

3

1IN+

Amplifier 1 non-inverting input

4 V

CC-

Negative supply pin for amplifier 1 and amplifier 2

5

2IN+

Amplifier 2 non-inverting input

6

2IN-

Amplifier 2 inverting input

7 2OUT

Amplifier

2

output

8 V

CC+

Positive supply pin for amplifier 1 and amplifier 2.

Absolute Maximum Ratings

(Note 2)

Symbol

Parameter

Rating

Unit

V

CC+

Supply voltage (Note 3)

18

V

V

CC-

-18

V

ID

Differential input voltage (Note 4)

±30

V

V

I

Input voltage (any input) (Note 3, 5)

±15

V

Duration of output short circuit to ground, one
amplifier at a time (Note 6)

Unlimited

T

J

Junction Temperature (Note 7)

150

°C

T

STG

Storage Temperature

-65 to 150

°C

Notes:

2. Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, and

functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions is not implied.

Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.

3. All voltage values, unless otherwise noted, are with respect to the midpoint between V

CC+

and V

CC–.

4. Differential voltages are at IN+ with respect to IN–.

5. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 V, whichever is less.

6. Temperature and/or supply voltages must be limited to ensure that the dissipation rating is not exceeded.

7. Maximum power dissipation is a function of T

J

(max),

θ

JA

,

and T

A

. The maximum allowable power dissipation at any allowable ambient temperature

is P

D

= (T

J

(max) – T

A

)/

θ

JA

. Operating at the absolute maximum T

J

of 150

°C can affect reliability.

Recommended Operating Conditions

Symbol

Parameter

Min

Max

Unit

V

CC+

Supply voltage (Note 3)

5 15

V

V

CC-

-5 -15

T

A

Operating Ambient
Temperature Range

APX4558 0

70

°C

APX4558I -40

105


Advertising