Maximum ratings, Thermal characteristics, Safe operating area – Diodes ZXTP19020DZ User Manual

Page 2: Derating curve, Collector-emitter voltage (v)

Advertising
background image

ZXTP19020DZ
Da

tasheet Number: DS33733 Rev. 2 - 2

2 of 7

www.diodes.com

November 2011

© Diodes Incorporated

A Product Line of

Diodes Incorporated

ZXTP19020DZ





Maximum Ratings

@T

A

= 25°C unless otherwise specified

Characteristic Symbol

Value

Unit

Collector-Base Voltage

V

CBO

-25 V

Collector-Emitter Voltage

V

CEO

-20 V

Emitter-Base Voltage

V

ECO

-4 V

Emitter-Base Voltage

V

EBO

-7 V

Continuous Collector Current (Note 6)

I

C

-6 A

Base current

I

B

-1 A

Peak Pulse Current

I

CM

-15 A



Thermal Characteristics

@T

A

= 25°C unless otherwise specified

Characteristic Symbol

Value

Unit

Power Dissipation (Note 4)
Linear derating factor

P

D

1.1
8.8

W

mW/°C

Power Dissipation (Note 5)
Linear derating factor

P

D

1.8

14.4

W

mW/°C

Power Dissipation (Note 6)
Linear derating factor

P

D

2.4

19.2

W

mW/°C

Power Dissipation (Note 7)
Linear derating factor

P

D

4.46
35.7

W

mW/°C

Power Dissipation (Note 8)
Linear derating factor

P

D

26.7

213

W

mW/°C

Thermal Resistance, Junction to Ambient (Note 4)

R

θJA

117

°C/W

Thermal Resistance, Junction to Ambient (Note 5)

R

θJA

68

°C/W

Thermal Resistance, Junction to Ambient (Note 6)

R

θJA

51

°C/W

Thermal Resistance, Junction to Ambient (Note 7)

R

θJA

117

°C/W

Thermal Resistance, Junction to Leads (Note 8)

R

θJL

4.69

°C/W

Operating and Storage Temperature Range

T

J,

T

STG

-55 to +150

°C

Notes:

4. For a device surface mounted on 15mm x 15mm x 0.6mm FR4 PCB with high coverage of single sided 1oz copper, in still air conditions.
5. Mounted on 25mm x 25mm x 0.6mm FR4 PCB with high coverage of single sided 1oz copper, in still air conditions.
6. Mounted on 50mm x 50mm x 0.6mm FR4 PCB with high coverage of single sided 2oz copper, in still air conditions.
7. As note 6 above measured at t<5 seconds.
8. Junction to case (collector tab). Typical


Thermal Characteristics

100m

1

10

10m

100m

1

10

50mm X 50mm 2oz Cu

Single Pulse

T

amb

=25°C

V

CE(sat)

Limited

100µs

1ms

10ms

100ms

1s

DC

Safe Operating Area

-I

C

C

o

lle

c

to

r C

u

rr

e

n

t (

A

)

-V

CE

Collector-Emitter Voltage (V)

0

20

40

60

80

100

120

140

160

0.0

0.4

0.8

1.2

1.6

2.0

2.4

50mm X 50mm

2oz Cu

25mm X 25mm

1oz Cu

15mmX15mm

1oz Cu

Derating Curve

Temperature (°C)

M

a

x P

o

w

e

r D

issi

p

a

ti

o

n

(

W

)

Advertising