11

8. Pack the spaces between and around the

grid with as much as coupling vendor
supplied grease as possible and wipe off
the excess until flush with the top of the
grid. Position seals on hubs to line-up with
grooves in cover. Position gaskets on
flange of lower cover half and assemble
covers so that the match marks are on the
same side.

FIG. 5H – COVER INSTALLATION

C

Do not o

.

Couplin

Failure
property

ry.

9. Ensure lube plugs are installed in cover.

AUTION: Coupling Failure

perate coupling without proper lubrication

g failure may occur.

to follow these instructions could result in

damage and/or moderate personal inju

Fastener Tightening
Torque Values

Size

Parallel

Offset

(P)

Angular

(x-y)

Hub Gap
+/- 10%

End Float

Physical

Limit (Min)

2xF

Cover Fastener

Tightening Torque

Values

Flange

Type

31 & 35

Maximum

Allowable

RPM

Lube Wt.

Max Inch Max Inch

Inch

Inch

In. Series

Fasteners

(lb*in)

In. Series

Fasteners

(lb*in)

lb

1040T

0.006

0.003

0.125

0.211

100

120

3600

0.12

1050T

0.008

0.004

0.125

0.212

200

250

3600

0.15

1060T

0.008

0.005

0.125

0.258

200

440

3600

0.19

1070T

0.008

0.005

0.125

0.259

200

440

1800

0.25

1080T

0.008

0.006

0.125

0.28

Installation Limits

8

200

825

1800

0.38

FIG. 5J – MISALIGNMENT & FASTENER TORQUE VALUES