OPERATION

1. Pre-start Checks
Before initial start of the pump, make the following

inspections:
a. Check alignment between pump and motor.
b. Check all connections to motor and starting device with

wiring diagram. Check voltage, phase, and frequency on

motor nameplate with line circuit.

c. Check suction and discharge piping and pressure gauges

for proper operation.

d. Check impeller adjustment, see specific section for proper

adjustment.

e. Turn rotating element by hand to assure that it rotates

freely.

f. Check driver lubrication.
g. Assure that pump bearings are properly lubricated.
h. Assure that coupling is properly lubricated, if required.
i. Assure that pump is full of liquid. (See 2. Priming) and all

valves are properly set and operational, with the discharge

valve closed, and the suction valve open.

j. Check rotation. Be sure that the drive operates in the direc-

tion indicated by the arrow on the pump casing, as serious

damage can result if the pump is operated with incorrect

rotation. Check rotation each time the motor leads have

been disconnected.

2. Priming
If the pump is installed with a positive head on the suction, it

can be primed by opening the suction and vent valve and

allowing the liquid to enter the casing.
If the pump is installed with a suction lift, priming must be

done by other methods such as foot valves, ejectors, or by

manually filling the casing and suction line.

3. Starting
a. Close drain valves and valve in discharge line.
b. Open fully all valves in the suction line.
c. Prime the pump.

NOTE: If the pump does not prime properly, or loses prime

during start-up, it should be shutdown and the condition

corrected before the procedure is repeated.

d. When the pump is operating at full speed, open the dis-

charge valve slowly. This should be done promptly after

start-up to prevent damage to pump by operating at zero

flow.

4. Operating Checks
a. Check the pump and piping to assure that there are no

leaks.

b. Check and record pressure gauge readings for future

reference.

c. Check and record voltage, amperage per phase, and kw if

an indicating wattmeter is available.

d. Check bearings for lubrication and temperature. Normal

temperature is 180° maximum.

e. Make all pump output adjustments with the discharge line.

5. Freezing Protection
Pumps that are shut down during freezing conditions should

be protected by one of the following methods.
a. Drain the pump; remove all liquids from the casing.
b. Keep fluid moving in the pump and insulate or heat the

pump to prevent freezing.

WARNING: Rotating Components Hazard

Do not operate pump without all guards in place.

Failure to follow these instructions could result in serious

personal injury or death and property damage.

WARNING: Rotating Components Hazard

Do not operate pump without all guards in place.

Failure to follow these instructions could result in serious

personal injury or death and property damage.

CAUTION: Cavitation Damage Hazard

Do not throttle the suction line to adjust the pump

output. Failure to follow these instructions could result in

property damage and/or moderate personal injury.

CAUTION: Bearing/Seal Damage Hazard

Do not let heated pump temperature rise above

150°F. Failure to follow these instructions could result in

property damage and/or moderate personal injury.

CAUTION: Seal Damage Hazard

Do not run pump dry, seal damage may occur.

Failure to follow these instructions could result in property

damage and/or moderate personal injury.