SERVICE INSTRUCTIONS

FOR AN HSC

3

PUMP

To Replace the Mechanical Seals and Bearings

without removing Upper Half of the Casing
NOTE:
In order to replace the mechanical seal and bearing

housing on the coupler end, you must use a spacer type

coupler.

1. Close valves on suction and discharge sides of pump. If

no valves have been installed, it will be necessary to drain

the system.

2. Remove the coupler guard. For spacer coupler, loosen the

capscrews which secure the coupler flanges to the

coupler hubs. Remove the coupler flanges and sleeve by

compressing the flanges and pulling out from beneath the

hubs or by loosening the allen set screws and sliding the

hubs back on the shafts. Remove the coupler hubs from

the pump shaft. For non-spacer couplers, loosen set

screws and slide flanges back on shafts and remove

rubber element.

3. Remove the capscrews from each of the bearing housings

and remove the bearing housings by placing two 2.0"

long full-threaded capscrews or allen set screws in the

jackscrew holes provided.

4. Bend back the lockwasher tab and remove both the lock-

washer and locknut from the outboard end of the shaft

(the opposite side of the coupling).

5. Remove the socket-head capscrews holding the gland

plates to the stuffing boxes.

16

CAUTION: Extreme Temperature Hazard

Allow pump temperatures to reach acceptable levels

before proceeding. Open drain valve. Do not proceed until

liquid stops coming out of drain valve. If liquid does not

stop flowing from drain valve, isolation valves are not seal-

ing and should be repaired before proceeding. After liquid

stops flowing from drain valve, leave drain valve open and

continue. Remove the drain plug located on the bottom of

the pump housing. Do not reinstall plug or close drain

valve until reassembly is completed. Failure to follow these

instructions could result in property damage and/or moder-

ate personal injury.

WARNING: Unexpected Start-up Hazard

Disconnect and lock out power before servicing.

Failure to follow these instructions could result in serious

personal injury or death and property damage.

IMPELLER

IMPELLER KEY

PIPE PLUG

GLAND PLATE

SOCKET HEAD

CAP SCREW
STUFFING BOX

BEARING HOUSING

JACK SCREW

LIP SEAL

INBOARD

BEARING

GREASE FITTING

COUPLING KEY

SHAFT

BEARING HOUSING

STUFFING BOX

DOWEL PIN

SUCTION SIDE

CASING GASKET

DISCHARGE SIDE

CASING GASKET

CASING RING

DOWEL PIN

CASING RING

“O” RING

MECHANICAL

SEAL

GLAND PLATE

STUFFING BOX

BEARING

LOCK WASHER

BEARING HOUSING

CAP SCREW

BEARING LOCKNUT

BEARING

HOUSING

STUFFING BOX

DOWEL PIN

OUTBOARD

BEARING

GREASE FITTING

BEARING HOUSING

JACK SCREW

LIP SEAL

GLAND PLATE

“O” RING

STUFFING BOX

“O” RING

IMPELLER

SNAP RING

CASING RING

CASING

PIPE PLUG

PIPE PLUG

BEARING HOUSING

CAP SCREW

CASING RING

DOWEL PIN

Impeller Wear Ring

Impeller Rings can be

added — Optional extra.

Standard Mechanical Self Flushing Seal

HSC

3

Cross-Section