The pumps run but do not build desired pressure – Xylem AquaForce Variable Speed Package System User Manual

Page 24

Advertising
background image

Cause

Remedy

The fuses are blown or breakers are tripped.

Check circuit breaker and fuses.

Transducer isolation valves are closed.

Make sure that the transducer isolation valves are in the

open position.

Automatic mode is faulty.

Check to see if the pump can be run in Manual mode on

the PLC.

The impeller is bound.

Check to see if you can turn the pump by hand. Check for

a bound impeller.

A pressure transducer is faulty.

Replace faulty pressure transducers.

Motor wiring is loose.

Make sure that motor wiring is securely connected.

Motor windings have lost insulation strength.

Test the motor leads with a megger in order to check the

motor windings.

Variable speed drive is wired incorrectly.

Check corresponding variable speed drive. Make sure

drive is wired correctly.

Motor is defective.

Repair or replace motor.

The pumps run but do not build desired pressure

Cause

Remedy

Pumps are running off their design curve.

Check the application. Is the system running in an open

discharge condition (excessive flow rate)? For example, is

the system filling a large irrigation line for the first time

of the season?

Pumps are running at less than full speed.

Check to see if the pumps are running at full speed. If

they are running less than full speed, they could be

experiencing electrical issues. Check the panel for power

status.

The inlet pressure does not match the project

specifications.

Check to see if the inlet pressure matches the project

specifications. Variations in inlet pressure can have

detrimental effects on performance.

A pipe is broken.

Check for broken pipes.

The transducer isolation valves are closed.

Check to be sure that the transducer isolation valves are

in the open position.

The NPSH is insufficient.

Check the NPSH. Are proper flooded conditions or

positive pressure being delivered to the pump station?

Check for air in the supply lines. Check for properly filled

supply tanks (if applicable). Excessive suction lift or

piping losses will limit the life expectancy of the pumps.

The pump station has lost its prime.

Check to be sure that the pump station has been primed

properly. Make sure that all pumps and components are

properly filled with water.

The pump rotation is incorrect.

Check the pump rotation. Proper rotation is indicated on

the pump volute. (See the pump IOM.)

A suction or discharge valve is closed or clogged.

Check the isolation valves and check valves. Are all

suction/discharge valves open? Could any valves be

plugged? Could the pumps be plugged?

The motor is not operating at the rated RPM.

Check the voltage and amperage. Check for possible

phase loss to the motor.

The impeller is worn or plugged.

Take the pump to an authorized pump repair facility.

The pump bearings are worn.

Take the pump to an authorized pump repair facility.

Troubleshooting

22