CP-Series Submersible Motors Installation, Operation and Maintenance Manual

5

Submersible Pump Installation Diagram

COMPONENTS REQUIRED FOR CORRECT INSTALLATION
• Control panel equipped with a main switch and thermal relay for

overload protection.

• Check valve at 30 feet distance from the delivery ports, plus an

additional non-return valve every 100-165 feet of piping.

• Gauge and gate valve at well mouth.
• Electronic probes or floats for protection against dry running.

RECOMMENDATIONS
• Secure the drop cable to the pipe every 6-10 feet of piping.
• Make sure the motor is installed at a safe distance from the bottom of

the well.

• Make sure there is a minimum distance of .13 inches between the

diameter of the pump and the internal diameter of the well.

• During operation, make sure that the water circulation speed around the

motor is per Section VI #1.

• Make sure that the minimum dynamic level of the water in the well is at

least 3 feet above the pump’s delivery port.

1 - Submersible pump
2 - Delivery pipe
3 - Drop cable
4 - Control panel
5 - Check valve
6 - Gauge
7 - Gate valve
8 - Level sensors for protection against dry

running.

9 - Cable clamp
10 - Pump bleed/priming cap

A - Distance between the clamps that secure

the drop cable to the delivery pipe.

B - Distance from the bottom of the well to

the electric motor.

Submersible Pump Installation Diagram