WARNING

Hazardous voltage

can shock, burn or

cause death.

ROTATION

NOTICE: INCORRECT ROTATION MAY CAUSE

DAMAGE TO PUMP AND VOIDS THE

WARRANTY.

Correct rotation is left-hand, COUNTER-CLOCK-

WISE when viewed from the motor end.

To reverse three phase motor rotation interchange any

two power supply leads.

INSTALLATION

Minimum and maximum liquid levels must be main-

tained for proper pump operation. See Figure 1.

Allow adequate space for servicing and ventilation.

Protect from freezing or flooding.

OPERATION

SPLASHING OR IMMERSING OPEN

DRIP PROOF MOTORS IN FLUIDS CAN

SHORT OUT MOTOR AND CAUSE

FIRE, SHOCK, BURNS OR DEATH.

NOTICE: PUMP MUST BE FULLY PRIMED BEFORE

OPERATION. DO NOT RUN PUMP DRY.

After stabilizing the system at normal operating con-

ditions, check the piping. If necessary, adjust the pipe
supports.

Do not run pump dry; damage to

mechanical seal will result. Do not run

against closed nozzle for prolonged

periods or damage to pump and piping

will result.

WARNING

Hazardous

voltage

WARNING

Hazardous

voltage

CAUTION

DESCRIPTION AND SPECIFICATIONS

The VB Series is a high pressure pump used for coolant
circulating systems.

ENGINEERING DATA

• Maximum Liquid Temperatures: 160°F (72°C)
• Maximum Suction Pressure 75 psi
• Pipe connections are 1" NPT suction and discharge.

¾" Hose Adapters are available.

• Capacities to 33 GPM
• Heads to 600 Feet (260) psi
• Rotation: Left hand, ie; COUNTERCLOCKWISE

when viewed from motor end.

PIPING

• Piping should be no smaller than the pump discharge.

Piping should be kept as short as possible, avoiding
unnecessary fittings to minimize friction losses.

• All piping MUST be independently supported and

MUST NOT place any piping loads on the pump.

• All joints MUST be airtight. Use 3 – 4 wraps of PTFE

tape to seal threaded connections.

WIRING AND GROUNDING

Install ground and wire according to
local and National Electrical Code
requirements.
Install an all leg disconnect switch
near the pump.
Disconnect and lockout electrical
supply before installing or servicing
pump.

Electrical supply MUST match pump’s name plate

specifications. Incorrect voltage can cause fire and/or
damage to the motor and voids warranty.
Motors not protected MUST be provided with con-

tactors and thermal overloads on single phase mo-
tors, or starters with heaters on three phase motors.
See motor nameplate.

Use only stranded copper wire to motor and ground.

The ground wire MUST be at least as large as the wire

to the motor. Wires should be color coded for ease of
maintenance.

Follow motor manufacturer’s wiring diagram on the

motor nameplate or terminal cover carefully.

FAILURE TO PERMANENTLY

GROUND THE PUMP, MOTOR AND

CONTROLS BEFORE CONNECTING

TO ELECTRICAL POWER CAN

CAUSE SHOCK, BURNS OR DEATH.

NON-FOOTED MOTOR

¼" NPT PLUG

WATER LEVEL

1" NPT PORT

(SUCTION)

BOTTOM OF TANK

2" MIN.

5" MIN.

3¼" MIN.

1" NPT PORT

(DISCHARGE)

Figure 1