Maximum allowable working pressure charts – Xylem GLSSV2 SSV Series Vertical Multi-Stage Pumps D1 User Manual

Page 15

Advertising
background image

13

Maximum Allowable Working Pressure Charts

-50

0

50

100

150

200

250

300

0

50

100

150

200

250

300

350

400

1SVA / 2SVA / 3SVA

VITON

TEMPERATURE (F)

MA

XIMUM ALL

OW

ABLE WORKING PRES

SURE (PSIG)

1SV, 2SV, 3SV, 4SV

304SS / 316SS (SVA, SVB, SVC, SVD)

-30 -14

1SVB / 2SVB / 3SVB / 4SVB

1SVC / 2SVC / 3SVC / 4SVC

1SVD / 2SVD / 3SVD / 4SVD

1 2

EPR

-50

0

50

100

150

200

250

300

0

100

400

200

500

300

600

700

VITON

TEMPERATURE (F)

MA

XIMUM ALL

OW

ABLE WORKING PRES

SURE (PSIG)

33SV, 46SV, 66SV, 92SV

316SS (CF8M)

FLANGE CLASS 150

FLANGE CLASS 300

-20

-14

EPR

-50

0

50

100

150

200

250

300

0

100

400

200

500

300

600

TEMPERATURE (F)

MA

XIMUM ALL

OW

ABLE WORKING PRES

SURE (PSIG)

33SV, 46SV, 66SV, 92SV

Cast Iron Class 35 (ASTM A48)

-20

-14

FLANGE CLASS 125

FLANGE CLASS 250

VITON

EPR

NOTES:
1 Pressure rating for

victaulic connections
2 Some staging may have

higher pressure rating.

See pages 55-56.

Advertising