Motor Data – Starts per Hour / Minimum Run Time
HP
Max Starts per Hour (evenly distributed)
Min. run time between starts (seconds)
1
15
75
1.5
13
76
2
12
77
3
9
80
5
8
83
7.5
7
88
10
6
92
15
5
100
20
5
110
25
5
115
30
4
120
40
4
130
50
3
145
60
3
170
75
3
180
NOTE(S)
1) Recommended motor starts per hour and minimum run time calculated based on NEMA standards MG1-12.44 in accordance to
manufacturers allowable tolerance for heat rise and insulation breakdown.
2) Applied voltage and frequency in accordance with NEMA MG1-12.44
3) Starts based on NEMA three phase design A and design B AC induction motors.
4) External load WK2 is equal to or less than the values listed in NEMA MG1-12.54
5) Applicable to all NEMA (JM, JP, T and TC frame) motors used for Goulds Pumps products.
6) Applicable to three phase motors only.