14

Motor Data – Starts per Hour / Minimum Run Time

HP

Max Starts per Hour (evenly distributed)

Min. run time between starts (seconds)

1

15

75

1.5

13

76

2

12

77

3

9

80

5

8

83

7.5

7

88

10

6

92

15

5

100

20

5

110

25

5

115

30

4

120

40

4

130

50

3

145

60

3

170

75

3

180

NOTE(S)

1) Recommended motor starts per hour and minimum run time calculated based on NEMA standards MG1-12.44 in accordance to

manufacturers allowable tolerance for heat rise and insulation breakdown.

2) Applied voltage and frequency in accordance with NEMA MG1-12.44
3) Starts based on NEMA three phase design A and design B AC induction motors.
4) External load WK2 is equal to or less than the values listed in NEMA MG1-12.54
5) Applicable to all NEMA (JM, JP, T and TC frame) motors used for Goulds Pumps products.
6) Applicable to three phase motors only.