Aquavar – Xylem IM154 R01 AQUAVAR User Manual

Page 2

Advertising
background image

AQUAVAR Controller Technical Data:

AQUAVAR Controller

Motor

Supply Voltage

Recommended

Part Nos.

Rated Output

Voltage

Current

40-60 Hz

Circuit Protection

(1)

04168321

2 HP

3 ph 230V

7A

Single Phase

15 Ampere

240 VAC ± 10%

04168331

3 HP

3 ph 230V

10A

Single Phase

15 Ampere

240 VAC ± 10%

04168371

5 HP

3 ph 460V

9A

Three Phase

15 Ampere

380-460 VAC ± 15%

04168491

7

1

2

HP

3 ph 460V

13

1

2

A

Three Phase

20 Ampere

380-460 VAC ± 15%

04168501

10 HP

3 ph 460V

17A

Three Phase

25 Ampere

380-460 VAC ± 15%

AQUAVAR Controller

(2)

Motor

Circuit Protection Circuit Protection

Part Rated Supply Voltage

Input

Input

Voltage Current

Single Phase

Three Phase

Number Output

Frequency

INPUT

(1)

INPUT

(1)

(HP)

40-60 Hz

(Hz)

Phase

(V)

(A)

Fuse Size (A)

Fuse Size (A)

04169131

5

220-240 VAC +/- 15% 48....62

1 or 3 ph 3 ph 230V

15

40

20

04169141

7

1

/

2

220-240VAC +/- 15%

48....63

1 or 3 ph 3 ph 230V

22

60

30

04169181

10

220-240VAC +/- 15%

48....64

1ph only 3 ph 230V

28

70

NA

04169151

10

220-240VAC +/- 15%

48....64

3ph only 3 ph 230V

28

NA

40

NOTE: (1) Recommended short circuit protection is UL Type T, very fast acting fuses.

(2) Dimensions are similiar to the 5, 7

1

/

2

and 10 HP, 3 phase, 460 Volt units.

Dimensions and Weights

Part Nos.

Weight

04168321

12 lbs.

04168331

12 lbs.

04168371

12 lbs.

04168491

22 lbs.

04168501

22 lbs.

For other technical data,

see Appendix B

of IM043R07.

NOTE: All motors must be

at least 3 phase, TEFC,

Class B design.

AQUAVAR

Ø195 (2–5 HP)

Ø280 (7

1

2

–10 HP)

100

185

* Dimensions are in mm.

1 inch = 25.4 mm