4 Hardware Description

4.1 Mounting


The iRIS 150 can be mounted to almost any surface by using suitable screws through the two internal
mounting pillars. These are exposed by removing the lid.

4.2 I/O Connector

All I/O and power supply terminations are via a small 12 way screw terminal block. The functions of the
connector terminals are shown in the table below.

Abbreviation

Description

AI1

Analogue Input #1

GND

Ground (Analogue)

AI2

Analogue Input #2

GND

Ground (Analogue)

DI1

Digital Input #1

GND

Ground (Digital)

DI2

Digital Input #2

GND

Ground (Digital)

DO1

Digital Output

SDI

SDI-12 data connection

+Vin

5-15Vdc External Power Supply

GND

0Vdc External Power Supply / Ground

Table 1- I/O Terminal Designations

4.2.1 Internal Lithium Battery

The iRIS has an internal AA size 3.6V, 2400mA/Hr lithium battery, which provides the power supply when no
external dc power supply is available. When external power is connected, the internal battery is completely
disconnected. The battery may be replaced by the user.

NOTE: 1) The internal battery is not intended for long-term use, rather as a back-up in the event of

loss of external power.
2) Standard AA batteries such as Alkiline, NiCad, NiMh, etc, cannot be used in the iRIS as
they are not of sufficient voltage to supply the iRIS.


4.2.2 External Power Supply

Although the iRIS is designed to operate solely from its internal battery for many months, you will typically
need to connect an external supply to the unit so that the internal battery remains in a charged state. Any
external dc power source ranging from 6 – 15 Vdc can be connected. A solar panel may also be connected
but will require a regulator to limit the voltage. A typical solar panel without regulation can generate voltage
up to 21V, which exceeds the iRIS 150 external dc input range.

The external power supply is protected against reverse connection or over-voltage by ultra-fast acting
protection devices and a self-resetting semiconductor fuse.