Xylem MOH2 Multi zone mixing module (obsolete) User Manual

Page 10

Advertising
background image

10

Installation and operation manual MOH2

www.lainginc.com

If you purchased the station on mounting rails
• Attach the station directly to the wall
• Observe the above advice for avoiding noise problems
• You can use the mounting rails to mark the mounting holes before drilling
If you purchased the station with cabinet
• Remove the front cover of the cabinet
• Install the station in the appropriate niche in the wall and attach it there
• Cover the station with plastic film to keep dirt out
• Use plaster to fill the space between the niche and the cabinet
• Reattach the front cover so that the cover is flush with the plaster surface
Calorimeter
• A parts kit for the attachment of a calorimeter can be ordered as an

option

• Leave enough space in the return of the boiler loop for installation
• There is no need for a sensor fitting on the feed side. The feed side

temperature sensor can be installed directly in the base module

Hydraulic connection

General guideline
• Attach the pipes taking care to avoid too much stress on the module
• To avoid noise, the station must not touch the wall or the mounting

fittings. Use rubber grommets.

• The boiler loop pipes must be insulated inside the wall to avoid noise.
Connection
• First connect the boiler loop return side to the MOH2. If necessary,

install a calorimeter here.

• Next, attach the boiler feed side to the MOH2.
• Attach the low temperature heating loops using compression fittings

starting from the left side. When using plastic tubes, observe the in-
structions of the system manufacturer.

Connection of calorimeter sensor

• The base module has a 1/2" connection for the dip tube of the calorimeter

next to the boiler feed connection.

• Install the dip tube of the calorimeter here.