Appendix A

XL Series Specifications

XL™ Series

Appendix A Specifications A-1

Sensor I/O Performance

General Analog Input (All Units)

Channels:

4 (Single Ended)

Resolution:

16-Bit Resolution (1 Part in 65536)

Accuracy:

±0.02% FS

Input Ranges:

0 to 5 Volts (All Channels)
0 to 500 mV (Additional Input Range Only
Available on Channel 1)
Accuracy ± 0.15%

Excitation

5.0V Switched, Ratiometric with
10mA (max load)

Accuracy

± 1.0 mV Over Load and Temperature Range

Frequency Input (All Units)

Input Range:

1 to 10 KHz at ± 75mVolts or greater
1 to 15 KHz at ± 1 Volt or greater

Input Amplitude:

± 5.0 V Max

Accuracy:

± 0.1%

Resolution:

1/10000 * Reading

Counter Input (All Units)

Type:

Switch closure or voltage pulse,
Internal 50k pull up resistor, falling
edge triggered.

Input Voltage:

0-5 Volts

Minimum Pulse Width:

5 mS

Input Frequency:

100Hz (max)

Digital I/O (All Units)

Channels:

2, Independently configured for input
or output

Input Voltage:

0-5 Volt

High Level:

3.5 V (min)

Low Level:

0.8 V (max)

Output Voltage
Low:

0.4 V (max)@ -5mA

High:

3.5V (min)@+5mA

4-20 mA Output (All Units)

Resolution:

0.25 µA

Pressure Sensor (H-350XL Only)

Accuracy
(Maximum percent of error in measurement)
Pressure:

Less than or equal to 0.02% of full scale output
(FSO) over temperature range referenced to a straight
line stretched from zero psi to maximum pressure

Temperature: Internal temperature ± 1°C over temperature range

Resolution

(Smallest change detectable in output signal)
Pressure:

1 part in 65,536 (0.002%)

Temperature: 1 part in 65,536 (0.002%)

Linearity
Less than 0.02% deviation from a straight line referenced to end
points

Pressure Hysteresis
Less than 0.01% of FSO

Long-term Stability
Accuracy drift is less than ± 0.05% of FSO per year

Response Times
Pressure only:

10-second measurement sequence

Pressure & Temp.: 10-second measurement sequence
Temperature only: 5-second measurement sequence

Pressure Range Options
Pressure

Depth

Accuracy

0 to 15 psi

0 to 34.60 feet ± 0.007 feet

0 to 30 psi

0 to 69.20 feet ± 0.014 feet

Custom calibration ranges available from 5 to 100 psi

Pressure Overload: Less than 2 times the rated pressure
Pressure Inlet:

1/8 in. NPT female fitting

Media Non-corrosive dry gases only
Hardware:

Pressure inlet plumbing installation kit available
(H-350-INS)

Shaft Encoder (H-510XL Only)

Resolution:

200 counts/rev

M ax rate:

15 rev/second