GENERAL INFORMATION

FEATURES

The WMX-Series are flanged electromagnetic flowmeters

for use in 3” to 10” pipe in municipal or industrial water and

wastewater applications where propeller meters have typically

been used in the past. Because the WMX has no moving

parts and has electrodes designed to discourage fouling, this

magmeter performs well and requires much less frequent

maintenance in applications where debris would impede

propeller meters. There is no rotor to stop turning or bearings

to wear out. Minimal straight pipe requirements allow WMX-

Series meters to be used in piping configurations where there

is little space between the meter and an elbow.

In chemical injection applications, the chemical injection point

must be placed downstream of the magmeter OR far enough

upstream for complete mixing to occur before the fluid

reaches the meter.

The submersible units, -168 option, are rated IP68 (NEMA 6P)

for applications where the meter may be under water up to a

depth of 3 meters for prolonged periods of time.

Rate and total indication are standard on both models. Units

are customer-selected and factory-set. No set-up is required.

The WMX101 is externally powered with 8-32 Vdc at 30

mA max (see NOTE in Specifications). Two Lithium 3.6V

“AA” batteries provide auxiliary power during power failures,

allowing the meter to continue recording flow rate and total

without interruption for the duration of the outage. Where

external power loss is infrequent, battery life exceeds 10 years.

The 20-foot power cable also provides pulse output for use

with a variety of Seametrics and other displays and controls for

remote reading, data logging, pulse-to-analog conversion, and

telemetry applications. High frequency pulse rate (required

for use with 4-20 mA converters) is standard; additional pulse

rates are optional.

The WMX104 is a battery-operated unit for use when pulse

output is not required. Two Lithium 3.6V “D” batteries provide

power and are replaceable with an approximate 1-year life

under continuous use, or more depending on the duty cycle.

An optional input/output cable can be installed post-factory if

needed for changing applications.

Welded steel epoxy-coated flow tube

Flanges, ANSI 150 lb. drilling

Dual durometer rubber liner

Power/Output cable port access, tamper-sealed

(NOTE: WMX101 comes with standard 20’ cable installed)