III. Auto-Drain Rain Gauge Installation

a. The Auto-Drain Rain Gauge requires a clear an unobstructed

mounting location to obtain accurate rainfall readings. There are two

holes drilled through the backing plate that may be used to mount the

Rain Gauge to a post.

IV.

Auto-Drain Rain Gauge Set Up and Use

a. The Hours knob can be used to change how often the rain gauge

empties. Set the knob to your specific application. (Usually 24 hours)

b. The Functions knob has 3 settings:

1. Off:

When not in use

2. Drain:

Manually Empty

3. Auto:

Drains per the Hours settings

c. Once the Hours and Function knobs have been set, verify the RG333

is mounted vertically, and there is no obstruction above the opening.


V.

Maintenance

a. The funnel and Auto-Drain Rain Gauge mechanism should be cleaned

periodically. An accumulation of dirt, bugs, etc. in the Auto-Drain Rain

Gauge funnel will adversely affect the readings. If necessary use a

bristle brush and flush with fresh water.

b. Replace the unit’s batteries annually. The Rain Gauge comes with two

AA size alkaline batteries. To access the batteries, unscrew the

Phillips head screw, located at the bottom of the unit. Remove cover

and replace batteries.

WARNING: Removing the batteries will reset the Rain Gauge’s Auto

function.