Model lsn, Transport, handling, storage, 1 transport, handling – Xylem LSNIH User Manual

Page 10: Lsn 100-english page 8, Pic 2

Advertising
background image

Installation, Operating and Maintenance Instruction

Model LSN


LSN 100-english

page 8

Revision 01

Article No 771076024

Issue

01/2010

Sizes

Suction nozzle

Discharge nozzle

DN

Forces in N

Torques in Nm

DN

Forces in N

Torques in Nm

Fx

Fy

Fz

F

Mx

My

Mz

M

Fx

Fy

Fz

F

Mx

My

Mz

M

40-25-160

40

880

770

700

1370

900

630

740

1330

25

530

490

600

920

630

420

490

920

40-25-200

40

880

770

700

1370

900

630

740

1330

25

530

490

600

920

630

420

490

920

40-25-250

40

880

770

700

1370

900

630

740

1330

25

530

490

600

920

630

420

490

920

50-32-160

50

1150 1050

950

1820

980

700

800

1450

32

630

600

740

1160 770

530

600

1120

50-32-200

50

1150 1050

950

1820

980

700

800

1450

32

630

600

740

1160 770

530

600

1120

50-32-250

50

1150 1050

950

1820

980

700

800

1450

32

630

600

740

1160 770

530

600

1120

50-32-315

50

1150 1050

950

1820

980

700

800

1450

32

630

600

740

1160 770

530

600

1120

65-40-160

65

1470 1300 1200 2300 1050 770

840

1550

40

770

700

880

1370 900

630

740

1330

65-40-200

65

1470 1300 1200 2300 1050 770

840

1550

40

770

700

880

1370 900

630

740

1330

65-40-250

65

1470 1300 1200 2300 1050 770

840

1550

40

770

700

880

1370 900

630

740

1330

65-40-315

65

1470 1300 1200 2300 1050 770

840

1550

40

770

700

880

1370 900

630

740

1330

80-50-160

80

1750 1580 1440 2760 1120 800

910

1650

50

1050

950

1150 1820 980

700

800

1450

80-50-200

80

1750 1580 1440 2760 1120 800

910

1650

50

1050

950

1150 1820 980

700

800

1450

80-50-250

80

1750 1580 1440 2760 1120 800

910

1650

50

1050

950

1150 1820 980

700

800

1450

80-50-315

80

1750 1580 1440 2760 1120 800

910

1650

50

1050

950

1150 1820 980

700

800

1450

100-65-160

100

2350 2100 1900 3670 1230 880

1020 1820

65

1300 1200 1470 2300 1050

770

840

1550

100-65-200

100

2350 2100 1900 3670 1230 880

1020 1820

65

1300 1200 1470 2300 1050

770

840

1550

100-65-250

100

2350 2100 1900 3670 1230 880

1020 1820

65

1300 1200 1470 2300 1050

770

840

1550

100-65-315

100

2350 2100 1900 3670 1230 880

1020 1820

65

1300 1200 1470 2300 1050

770

840

1550

125-80-160

125

2765 2485 2240 4350 1470 1050 1330 2140

80

1580 1440 1750 2760 1120

800

910

1650

125-80-200

125

2765 2485 2240 4350 1470 1050 1330 2140

80

1580 1440 1750 2760 1120

800

910

1650

125-80-250

125

2765 2485 2240 4350 1470 1050 1330 2140

80

1580 1440 1750 2760 1120

800

910

1650

125-80-315

125

2765 2485 2240 4350 1470 1050 1330 2140

80

1580 1440 1750 2760 1120

800

910

1650

125-80-400

125

2765 2485 2240 4350 1470 1050 1330 2140

80

1580 1440 1750 2760 1120

800

910

1650

125-100-200 125

2750 2500 2240 4350 1470 1050 1330 2140

100

2100 1900 2350 3670 1230

880

1020 1820

125-100-250 125

2750 2500 2240 4350 1470 1050 1330 2140

100

2100 1900 2350 3670 1230

880

1020 1820

125-100-315 125

2750 2500 2240 4350 1470 1050 1330 2140

100

2100 1900 2350 3670 1230

880

1020 1820

125-100-400 125

2750 2500 2240 4350 1470 1050 1330 2140

100

2100 1900 2350 3670 1230

880

1020 1820

150-125-250 150

3500 3150 2850 5500 1750 1230 1450 2560

125

2500 2240 2750 4350 1470 1050 1330 2140

150-125-315 150

3500 3150 2850 5500 1750 1230 1450 2560

125

2500 2240 2750 4350 1470 1050 1330 2140

150-125-400 150

3500 3150 2850 5500 1750 1230 1450 2560

125

2500 2240 2750 4350 1470 1050 1330 2140

200-150-250 200

4700 4200 3780 7350 2280 1610 1850 3350

150

3150 2850 3500 5500 1750 1230 1450 2560

200-150-315 200

4700 4200 3780 7350 2280 1610 1850 3350

150

3150 2850 3500 5500 1750 1230 1450 2560

200-150-400 200

4700 4200 3780 7350 2280 1610 1850 3350

150

3150 2850 3500 5500 1750 1230 1450 2560

4. Transport, Handling, Storage

4.1 Transport, Handling

Check the pump / pump unit immediately upon
delivery / receipt of despatch for damage or
missing parts.

The pump / pump unit must be transported
carefully and by competent personnel. Avoid
serious impacts.

Keep the pump/pump unit in the same position in
which it was supplied from the factory. Take note
of the instructions on the packaging.

The suction and discharge side of the pump must
be closed with plugs during transport and storage.

Dispose of all packing materials in accordance
with local regulations.

Lifting devices (e.g. fork-lift truck, crane, crane
device, pulleys, sling ropes, etc.) must be
sufficiently strong and must only be used by
authorized persons. The weight of the pump /
pump unit is given in the data sheet.

The pump / pump unit may only be lifted by solid
points such as the casing, flanges or frame.
Picture 2 shows the correct method of carrying by
crane.

pic 2

Do not stand underneath suspended loads.
Take note of the general regulations on
prevention of accidents.
The pump / pump unit must be secured against
tipping over and slipping until it has been fixed
in its final location.

Sling ropes must not be fixed to ends of shafts
or the ring loops of the motor.

Slipping out of the pump / pump unit of the
transport lifting device can cause damages to
persons and things.

Advertising