Model lsn, 4 drive – Xylem LSNIH User Manual

Page 13

Advertising
background image

Installation, Operating and Maintenance Instruction

Model LSN


LSN 100-english

page 11

Revision 01

Article No 771076024

Issue

01/2010

coupling. For the exact characterization of your
coupling refer to data sheet and / or order
confirmation.

pic 4 - Alignment of coupling with gauge and ruler

pic 5 - Alignment of coupling with spacer

Control alignment of coupling again in operation
warm condition and on system pressure (if
available) and correct, if necessary. Pay
attention to chapter 6 beforehand! It must be
possible to turn the unit easily and harmoniously
by hand.

Improper alignment of the unit can lead to
damages at coupling and unit!

Mount coupling guard after alignment and
before start-up.

5.3.2 Coupling Guard

Acc. to accident prevention regulations the
pump must only be operated with coupling
guard.

Care has to be taken, that the used coupling
guard consits of non-sparking material.

Parts:

Assembly:





5.4 Drive

On selecting the motor size care has to be taken, that
the requirements acc. to ISO 5199 are fulfilled. Note
the

Operating

Instructions

of

the

motor

manufacturer.

On application in zone 1 and 2 a motor with
valid Atex-certification must be used.