Sizes

Suction nozzle

Discharge nozzle

DN

Forces in N

Torques in Nm

DN

Forces in N

Torques in Nm

Fx

Fy

Fz

F

Mx

My

Mz

M

Fx

Fy

Fz

F

Mx

My

Mz

M

LS, LC

125-330

150 4000 3600 3240 6280 2000 1400 1640 2920 125 2840 2560 3160 4960 1680 1200 1520 2440

125-500

150 4000 3600 3240 6280 2000 1400 1640 2920 125 2840 2560 3160 4960 1680 1200 1520 2440

150-500

200 5360 4800 4320 8360 2600 1840 2120 3840 150 3600 3240 4000 6280 2000 1400 1640 2920

200-260

250 6680 5960 5400 10440 3560 2520 2920 5240 200 4800 4320 5360 8360 2600 1840 2120 3840

200-350

250 6680 5960 5400 10440 3560 2520 2920 5240 200 4800 4320 5360 8360 2600 1840 2120 3840

200-400

250 6680 5960 5400 10440 3560 2520 2920 5240 200 4800 4320 5360 8360 2600 1840 2120 3840

200-500

250 6680 5960 5400 10440 3560 2520 2920 5240 200 4800 4320 5360 8360 2600 1840 2120 3840

250-315

300 8000 7160 6440 12520 4840 3440 3960 7120 250 5960 5400 6680 10440 3560 2520 2920 5240

250-350

300 8000 7160 6440 12520 4840 3440 3960 7120 250 5960 5400 6680 10440 3560 2520 2920 5240

250-400

300 8000 7160 6440 12520 4840 3440 3960 7120 250 5960 5400 6680 10440 3560 2520 2920 5240

250-500

300 8000 7160 6440 12520 4840 3440 3960 7120 250 5960 5400 6680 10440 3560 2520 2920 5240

300-400

350 9320 8360 7520 14600 6200 4400 5080 9120 300 7160 6440 8000 12520 4840 3440 3960 7120

300-450

350 9320 8360 7520 14600 6200 4400 5080 9120 300 7160 6440 8000 12520 4840 3440 3960 7120

300-500

350 9320 8360 7520 14600 6200 4400 5080 9120 300 7160 6440 8000 12520 4840 3440 3960 7120

350-450

400 10640 9560 8600 16680 7760 5520 6360 11440 350 8360 7520 9320 14600 6200 4400 5080 9120

400-400

400 10640 9560 8600 16680 7760 5520 6360 11440 400 9560 8600 10640 16680 7760 5520 6360 11440

600-600

600 15920 14360 12920 25000 16160 11520 13280 23920 600 14360 12920 15920 25000 16160 11520 13280 23920

LCP

125-500

150 5000 4500 4050 7850 2500 1750 2050 3650 125 3550 3200 3950 6200 2100 1500 1900 3050

150-500

200 6700 6000 5400 10450 3250 2300 2650 4800 150 4500 4050 5000 7850 2500 1750 2050 3650

200-260

250 8350 7450 6750 13050 4450 3150 3650 6550 200 6000 5400 6700 10450 3250 2300 2650 4800

200-350

250 8350 7450 6750 13050 4450 3150 3650 6550 200 6000 5400 6700 10450 3250 2300 2650 4800

200-400

250 8350 7450 6750 13050 4450 3150 3650 6550 200 6000 5400 6700 10450 3250 2300 2650 4800

200-500

250 8350 7450 6750 13050 4450 3150 3650 6550 200 6000 5400 6700 10450 3250 2300 2650 4800

250-315

300 10000 8950 8050 15650 6050 4300 4950 8900 250 7450 6750 8350 13050 4450 3150 3650 6550

250-350

300 10000 8950 8050 15650 6050 4300 4950 8900 250 7450 6750 8350 13050 4450 3150 3650 6550

250-400

300 10000 8950 8050 15650 6050 4300 4950 8900 250 7450 6750 8350 13050 4450 3150 3650 6550

250-500

300 10000 8950 8050 15650 6050 4300 4950 8900 250 7450 6750 8350 13050 4450 3150 3650 6550

300-400

350 11650 10450 9400 18250 7750 5500 6350 11400 300 8950 8050 10000 15650 6050 4300 4950 8900

300-450

350 11650 10450 9400 18250 7750 5500 6350 11400 300 8950 8050 10000 15650 6050 4300 4950 8900

300-500

350 11650 10450 9400 18250 7750 5500 6350 11400 300 8950 8050 10000 15650 6050 4300 4950 8900

350-450

400 13300 11950 10750 20850 9700 6900 7950 14300 350 10450 9400 11650 18250 7750 5500 6350 11400

400-400

400 13300 11950 10750 20850 9700 6900 7950 14300 400 11950 10750 13300 20850 9700 6900 7950 14300

600-600

600 19900 17950 16150 31250 20200 14400 16600 29900 600 17950 16150 19900 31250 20200 14400 16600 29900

4. Transport, Handling, Storage

4.1 Transport, Handling

Check the pump / pump unit immediately upon

delivery / receipt of despatch for damage or
missing parts.

The pump / pump unit must be transported

carefully and by competent personnel. Avoid
serious impacts.

Keep the pump/pump unit in the same position in

which it was supplied from the factory. Take note
of the instructions on the packaging.

The suction and discharge side of the pump must

be closed with plugs during transport and storage.

Dispose of all packing materials in accordance
with local regulations.

Lifting devices (e.g. fork-lift truck, crane, crane

device, pulleys, sling ropes, etc.) must be
sufficiently strong and must only be used by
authorized persons. The weight of the pump /
pump unit is given in the data sheet.

The pump / pump unit may only be lifted by solid

points such as the casing, flanges or frame.

Picture 2 shows the correct method of carrying by
crane.

pic 2

Do not stand underneath suspended loads.
Take note of the general regulations on
prevention of accidents.
The pump / pump unit must be secured against
tipping over and slipping until it has been fixed
in its final location.

Sling ropes must not be fixed to ends of shafts
or the ring loops of the motor.

Advertising