Installation, Operating and Maintenance Instruction

Model LS, LC, LCP


LS 100-english

page 10

Revision 02

Artikel No. 771073402

Issue

01/2010

Slipping out of the pump / pump unit of the
transport lifting device can cause damages to
persons and things.

4.2 Storage / Conservation

Pumps or units, which are stored over a longer period
before start-up (max. 6 months), must be protected
from moisture, vibrations and dirt (e.g. by wrapping in

oil paper or plastic). Pumps must basically be stored in
a place where they are protected from the weather,
e.g. under dry cover. During this time, all suction and
discharge branches and all other intakes and outlets
must be closed with dummy flanges or plugs.
For longer periods of storage conservation
measurements at machined surfaces and packing with
moisture protection can be necessary!

5. Mounting / Installation

5.1 Mounting of Pump / Unit

5.1.1 Mounting of pump on a base frame
The pump and motor (= pump unit) must be provided
with a base frame made of steel or cast iron or a
fabricated (welded) frame, where this does not exist
already or if it is not included in the delivery. This base
frame must be placed on a foundation which can
withstand all loads that arise during operation (refer to
chapter 5.1.2).

When mounting the pump onto the base frame the
following must to be noticed:

The base frame must be solid, so that there won’t

occur any twists or vibrations during the operation.

The mounting surfaces of the pump feet and

motor on the base frame must be flat (machining
is recommended). Bracing of the pump leads to
premature breakdown of the pump and to a loss of
warranty.

The drillings for the pump mounting must be in

such a way, that safe fastening is guaranteed.

Between pump and motor shaft an adequate

space must be left depending on the used
coupling, refer to chapter 5.3.

Between pump and base frame there must be an

adequate shimming, so that in the case of
replacement of the pump the equal height
between bottom and centreline can be adjusted
(recommended vertical adjustment 4 to 6 mm).

Align pump and motor, refer to chapter 5.3, as

well.

5.1.2. Mounting the unit to a foundation
The place, where the pump is mounted must be
prepared acc. to the dimensions of the dimensional
drawings. The concrete foundations should have
sufficient firmness acc. to DIN 1045 or equal standard
(min. BN 15), to ensure a secure, functional mounting.
The concrete foundation must have set, before the
unit is erected. Its surface must be horizontal and
even.

Sufficient space must be provided for
maintenance and repair work, especially for
replacing the drive motor or the complete pump
unit. The motor fan must be able to take in
enough cool air, and the intake grille must
therefore be at least 10 cm away from any wall,
etc.

For the set of anchor bolts according recesses

must be provided. If that is not the case, concrete
expansion bolts resp. epoxy capsule anchor bolts
can be used.

When mounting the pump on the foundation it

must be adjusted at the discharge nozzle by
means of a spirit-level (at discharge nozzle). The
permitted deviation is 0,2 mm/m. After inserting
the foundation bolts they must be cast in the
foundation with concrete. After setting of the grout
the coupling alignment must be checked
according

chapter

5.3.1

and

possible

misalignments must be corrected by adjusting
foundation frame in the area of the drive motor.
The smoothness of the base frame must be 0,2
mm/m before it is filled up resp. fastened. For
adjustment levelling shims or levelling screws
(optional, not delivered standard wise) can be
used. Levelling shims must be inserted next to the
foundation anchors and must lie plainly. After that
fasten foundation bolts symmetrically but only
slightly. Fill in base frame with non shrinking grout.

Notice:

Avoid air bubbles (e.g. by vibrating).
Check that the grout has properly set and

hardened.

Take care for the after-treatment of the concrete

acc. to DIN 1045.

After setting, tighten the foundation anchor evenly and
firmly. Check alignment of coupling acc. to chapter
5.3.1 and re-adjust, if necessary. Further, check that
all screws between pump / motor and the base frame
fit snugly.
Although the original LS- resp. LCP-base frames are
designed solidly, the grouting of the adjusted base
frames is absolutely necessary.

If vibrations are transmitted to the foundation from

adjoining components, it must be guarded through
adequate vibration damping padding (vibrations
from outside can impair the bearing).

To prevent vibrations being transmitted to

adjoining components, the foundation should be
laid on a suitable insulating base.

The size of these insulating pads will vary,
depending on circumstances, and should
therefore be determined by an experienced
specialist.