Installation, Operating and Maintenance Instruction

Model LS, LC, LCP


LS 100-english

page 12

Revision 02

Artikel No. 771073402

Issue

01/2010

be checked by means of a tracer, gauge or dial
gage; refer to pic. 4 and 5.

The permitted tolerances for your coupling are

shown in the operating instructions of the
coupling. For the exact characterization of your
coupling refer to data sheet and / or order
confirmation.

pic 4 - Alignment of coupling with gauge and ruler

pic 5 - Alignment of coupling with spacer

Control alignment of coupling again in operation
warm condition and on system pressure (if
available) and correct, if necessary. Pay
attention to chapter 6 beforehand! It must be
possible to turn the unit easily and harmoniously
by hand.

Improper alignment of the unit can lead to
damages at coupling and unit!

Mount coupling guard after alignment and
before start-up.

5.3.2 Coupling Guard

Acc. to accident prevention regulations the
pump must only be operated with coupling
guard.

Care has to be taken, that the used coupling
guard consists of non-sparking material.


Parts:

Assembly:





5.4 Drive

On selecting the motor size care has to be taken, that
the requirements acc. to ISO 5199 are fulfilled. Note
the

Operating

Instructions

of

the

motor

manufacturer.

On application in zone 1 and 2 a motor with
valid Atex-certification must be used.