11

© 2000 - INLINE, Inc. CD100 / CD110 Court DirectorSystem Operation Manual - V. 1.0 11/30/2000

COMMAND CODE STRUCTURE AND DELIMITERS

All commands sent to the CD100 must contain a leading code, the command code, and an ending
code. Each command must be completely executed before the unit will accept a new command. The
unit can be set to recognize six sets of leading and end codes (delimiters) when using an RS-232
remote: parentheses ( ), brackets [ ], braces{ }, slashes \ /, less and greater than < >, and signs !#.
The factory default serial delimiters are [ ].
Note: The CD100 will ignore commands with no delimiters or the wrong delimiters.

A complete command consists of:

[

The leading code

CH3

The command code.

]

The ending code


Example: [CH3] directs the CD100 to select channel 3.


SERIAL CONTROL CABLE WIRING

When controlling only one Court Director System, connect the RS-232 cable as follows:

Controller Transmit

to

CD100 Receive

Controller Ground

to

CD100 Ground

Controller Receive

to

CD100 Transmit


When controlling multiple Court Director Systems, connect the RS-232 cable as follows:

Controller Transmit

to

Each CD100 Receive

Controller Ground

to

Each CD100 Ground

Controller Receive

to

Only one CD100 Transmit

When controlling multiple units, the Controller Receiver Terminal and each
CD100
Transmit Terminal is left unconnected. The CD100 Transit Lines
may not be connected together, otherwise signal contention from multiple
units will result. Therefore, “receive” information is not avail-able to the
controller in this configuration. Each unit must be set to different delimiters.


Court Director™ System Serial Commands*

Note: If the judge override function is active, the only serial commands that may be executed are:
ACIx, CMDCDx, OVERx and RESx. The INVALID MODE response will be given to other commands.

Command

Description

AC13

set communications port baud rate to 1200

AC14

set communications port baud rate to 2400

AC15

set communications port baud rate to 4800

AC16

set communications port baud baud rate to 9600**

AC17

set communications port baud baud rate to 19,200

AC18

set communications port baud baud rate to 38,400

ACIA3

set projector port baud rate to 1200

ACIA4

set projector port baud rate to 2400

ACIA5

set projector port baud rate to 4800

ACIA6

set projector port baud baud rate to 9600**