6

CTL101 Operation Manual - V1.3 03/22/02

©2002 - INLINE, Inc.

GND

RCV -

RCV+

+5V

1

3

3

1

2

4

2

4

CTL131 Remote Sensor

Set switch on rear of CTL101 to “EXT”

CTL101
IR Sensor Input

CTL131

CAUTION: Pay close attention NOT to reverse the +5V and GND connections.
Pin 1 and 4 are marked on the circuit board next to the connector.

0 to 500ft use 20 AWG min, 500 to 1000ft use 18 AWG min.

1

7

PWR

3

5

2

4

6

8

GND

CTL101 Contact Closure Inputs

CTL101 Supplies power

Set Dip Switches Bank2, Switches 1 and 2 to ON (Enabled)

CTL101
Contact Closure Input

NOTE: Current through each contact is @ 7mA.

1

7

PWR

3

5

2

4

6

8

GND

CTL101 Contact Closure Inputs

Inputs Isolated (Total Isolation provide by Optical Isolators)

Set Dip Switches Bank2, Switches 1 and 2 to OFF (Disabled)

CTL101
Contact Closure Input

NOTE: Current through each contact is @ 7mA.

+5 VDC
External
Power supply