Extron Electronics CTL101 User Manual

Page 8

Advertising
background image

4

CTL101 Operation Manual - V1.3 03/22/02

©2002 - INLINE, Inc.

Diagram D on page 10). The mouse type emitter attaches directly over the IR sensor of
the device being controlled (when used to control a single unit) or can be mounted up to
three feet away from the IR controlled devices when used to control multiple units.
Note: Emitters are to be used for local control of video equipment only (i.e. the video
equipment and the CTL101 are in the same room).

Do not place the CTL101 in a location where the unit’s sensor window
will detect the emitter signal, or in an area in which the signal could feed
back into the unit. This condition is evident whenever a remote control
command is issued and the remote light on the CTL101 remains "ON"
even after the remote control button is released.


Œ For Remote Sensor Applications - Connect the CTL131DB / CTL131DW IR Remote

Sensor to the IR Sensor Input Port (see the Wiring Diagram on page 6 and Application
Diagram D
on page 10). The sensor can be mounted in a remote location and can relay
signals to the CTL101 from up to 1000 feet away. Set the Sensor Mode button to the
EXT position.

6.) Turn on - the computer, monitor, INLINE equipment and all other connected / controlled

devices.


7.) Apply power to the CTL101 - using the IN9230 power cord (included). The power LED on

the front of the unit will illuminate.


8.) Set-Up the Terminal Emulation Program. Users can access the Set-Up Menu by typing an

Asterisk (*). Complete details are provided on pages 16 - 23.


CTL101 SERIAL PORT WIRING DIAGRAMS


Full Duplex RS-232

Default, Switch Bank 1 Switches 1-6 set to 0

CTL101
Serial Port

Computer Serial Port
(DB-9 Connector)

TX+

RX+

GND

1

5

3

2

5

3

TX

RX

GND

Advertising