IEC Power Panel

The IEC Power Panel consists of an On/Off switch, a fuse cover and two male
power connectors. (See Figure 4-1.) The second connector is provided for a
Redundant power supply.

Standard Power Supply

The Matrix 100 Series switcher/router has an auto-switching power supply that
operates from any input voltage from 90 to 260 VAC, 50/60 Hz. No equipment
changes are necessary.

Fuse

Fuse Type = 5mm x 20mm
Fuse Rating = 240V, 0.8A Super Slo Blo

Power Switch

Power Switch -

1 = On
0 = Off

Figure 4-1. IEC Power Panel: Power Switch, Fuse and Power Connectors

Redundant Power Supply (optional)

To improve equipment reliability in critical applications, the Matrix 100 can be
configured with a redundant internal power supply. With this option, the
Matrix 100 will automatically switch to the backup supply if the primary supply
fails. If the Matrix 100 switches to the backup power supply, it continues to
operate without interruption, and sends a command to the Host system to
indicate a change in status. If the Matrix has a QuickSwitch Front Panel
Controller, the Power LED will flash to alert the user that a power failure has
occurred.

_______ To install this optional power supply, see procedure on page 4-5.

QuickSwitch Front Panel Controller

The QuickSwitch Front Panel Controller (QS-FPC) provides local control of all
Matrix 100 functions. This optional feature is intended to supplement normal
RS-232 computer control with a local or remote operator control.