Extron Electronics MGP Pro Series User Guide User Manual
Page 78

MGP Pro Series • Remote Configuration and Control
72
Command
ASCII (Telnet)
(Host to Processor)
URL Encoded (Web)
(Host to Processor)
Response
(Processor to Host)
Additional Description
Event Control
Read event buffer
memory
27
E
X12%
,
X12^
,
X12&
,
X12*
E
}
W
X12%
,
X12^
,
X12&
,
X12*
E
|
X13(
]
Read the contents of a
specific section of a memory
buffer for event number
X12%
.
X12%
= event number, 1-99.
X12^
= event buffer.
For
X12^
:
0 = receive
1 = user
2 = NVRAM.
X12&
= event buffer offset,
0 to max. buffer size.
X12*
= Event data size.
For
X12*
:
b = bit
B = byte (8 bits)
S = short (16 bits)
L = long (32 bits).
X13(
= data element value
in ASCII from event buffer
(leading zeros suppressed).
Write event to
memory buffer
24, 27
E
X12%
,
X12^
,
X12&
,
X12(
,
X12*
E
}
W
X12%
,
X12^
,
X12&
,
X12(
,
X12*
E
|
Ewr
X12%
,
X12(
]
Write event
X12%
to buffer
X12^
, offset by
X12&
. Include
data
X12(
, size
X12*
.
X12(
= event data to write.
Read string from event buffer memory
27
E
X12%
,
X12^
,
X12&
,
X13!
FE
}
W
X12%
,
X12^
,
X12&
,
X13!
FE
|
{string}
]
Read string from event
X12%
,
buffer
X12^
, offset by
X12&
,
X13!
bytes.
X13!
= number of bytes to
read.
Write string to event buffer memory
24 27
E
X12(
,
X12%
,
X12^
,
X12&
FE
}
W
X12(
, %2A
X12%
,
X12^
,
X12&
FE
|
Ewr
X12%
,
X12(
]
Write data string
X12(
from
event
X12%
, buffer
X12&
, offset
by
X12&
.
Start events
24, 27
E
1AE
}
W 1AE
|
Ego
]
Initiate all programmed
events.
Stop events
24, 27
E
0AE
}
W 0AE
|
Est
]
Stop all programmed events.
Read number of
events running
E
AE
}
W AE
|
Enm nn
]
With tagged
response – verbose
modes 2 and 3:
Enm nnnnn
nn = 2-digit number.
nnnnn = 5-digit number.