48

Command and Response Table for IP SIS Commands

Symbol definitions

X3)

= ISS name

(Up to 240 alphanumeric characters)

NOTE: The following characters are invalid or not recommended in the name: {space} + ~ , @ = ` [ ] { } < > ‘ “ ” ; : | \ and ?.

X3!

= GMT date and time (for set)

In the format: MM/DD/YYHH:MM:SS where:
MM = month:

01

(Jan) through

12

(Dec)

DD = day:

01

through

31

YY = year:

00

through

99

HH = hour:

00

through

23

MM = minutes:

00

through

59

SS = seconds:

00

through

59

X3@

= Date and time (for read)

In the format: Day,•DDMmmYYYYHH:MM:SS where:
Day = weekday:

Mon

through

Sun

DD = date:

01

through

31

Mmm = month:

Jan

through

Dec

YYYY = year:

2000

through

2099

HH = hour:

00

through

24

MM = minutes:

00

through

59

SS = seconds:

00

through

59

X3#

= IP address

nnn.nnn.nnn.nnn

X3$

= Password

12 alphanumeric characters

X3%

= Hardware (MAC) address

nn-nn-nn-nn-nn-nn

X3^

= Number of open connections

0

– 255

Command and response table

Command Function

SIS Command

(Host to Unit)

Response

(Unit to Host)

Additional description

Set ISS name (location)

EX3)

CN

}

Ipn•

X3)]

Read ISS name (location)

ECN

}

X3)]

Set GMT/date

EX3!

CT

}

Ipt•

X3@]

NOTE: The date and time entered should be Greenwich Mean Time (GMT).

Read GMT/date

E

CT

}

X3@]

Set IP address

EX3#

CI

}

Ipi•

X3#]

The switcher sends the response, but
the host may not receive it.

Read IP address

ECI

}

X3#]

Read hardware address

ECH

}

X3%]

Read # of open connections

ECC

}

X3^]

Set administrator password

E

X3$

CA

}

Ipa•

X3$]

Read administrator password

E

CA

}

X3$]

Set user password

E

X3$

CU

}

Ipu•

X3$]

Read user password

E

CU

}

X3$]

NOTE: When the computer is connected to the switcher via the RS-232 link, the Admin and User password fields are not masked. If a