Receiver Jumpering

By default, the receiver is unidirectional, configured to send serial data from the transmitter
to the receiver, only. If the system has only one receiver, this jumper can be repositioned to
enable bidirectional communication as follows:

1.

If applicable, disconnect all cables, remove the receiver from its installation location, and
remove any mounting brackets installed.

2.

Remove the two screws from either side of the receiver (four screws total) and lift the
top cover off of the receiver (see figure 2 below).

3.

Locate jumper JMP1 on the serial data (top) board and shift the jumper to bridge the
jumper block (see figure 2 below).

4.

Place the top cover back into place.

5.

Reinstall the four screws removed in step 2. If any mounting brackets were removed in
step 1, put them back into position as you reinstall the screws.

6.

If applicable, reinstall the receiver and reconnect all cables.

INPUT

BUFFERED

OUTPUT

OUTPUT

PO

WER

12V

.5A MAX

MT

P R

L 1

5H

D

RS

ON

1

2

3

4

5

6

H SYNC +

V SYNC +

C SYNC

SOG

VIDEO

END UNIT

RS-232

Tx

Rx

Jumper block JMP1
inside box.

JMP1

JMP2

JMP3

Unjumpered for

Unidirectional

Jumpered for

Bidirectional

Remove 4 screws,
lift top straight up.

Figure 2.

Opening the Receiver and Setting the Directional Jumpers