Edid minder configuration, Twisted pair cable termination – Extron Electronics MTP T 15HD A User Guide User Manual
Page 20

MTP T 15HD A Architectural Series • Installation
14
EDID Minder Configuration
The MTP T 15HD A D unit supports emulation of factory-installed EDID information through
EDID Minder.
To use factory-installed EDID information:
1.
If you have not already done so, connect the source device to the MTP 15HD
transmitter. Do not power on the source device at this time.
2.
Set the rear panel DIP switch (see
d
) to the required frequency (50 or
60 Hz).
NOTE: When the rotary dial (see
e
) is set to position 0, the frequency
DIP switch position is ignored.
3.
Set the rotary dial (see
e
) to the required position (see figure 15 for specific
EDID and its corresponding rotary switch position).
Positions 1 through F are factory installed. Position 0 is not used.
Rotary Switch
Position
Resolution
0
Not used
1
800x600
2
1024x768 (default)
3
1280x720
4
1280x768
5
1280x800
6
1280x1024
7
1360x768
8
1366x768
9
1400x1050
A
1400x900
B
1600x900
C
1600x1200
D
1680x1050
E
1920x1080
F
1920x1200
Figure 15.
EDID Settings Table