Step 3 — run all cables, Step 4 — install cable retractors (optional), Step 5 — install power module (optional) – Extron Electronics TLP Pro 720C Setup Guide User Manual

Page 4: Step 6 — aap assembly, Tlp pro 720c • setup guide (continued)

Advertising
background image

4

TLP Pro 720C • Setup Guide (Continued)

Step 3 — Run all Cables

Run all cables necessary to support the AC connector, the cables stored in the cubby, and all planned AAP connectors. Run the
cables below the table and through the hole that was cut in

Step 2

. Leave enough slack in the cables to connect or route them

before the cubby is installed in the table. Leave enough space under the enclosure for the external power supply and connection
of AV cables and the network connection for the TLP Pro 720C.

Step 4 — Install Cable Retractors (Optional)

If required, Extron cable retractors should be installed in the enclosure at this stage. For complete information about retractors
and how to install them, see the Retractors User Guide, which is available from the Extron website (

www.extron.com

).

Step 5 — Install Power Module (Optional)

ATTENTION:

For units that are used in North America, only
use AC power modules that are UL Listed Model
“Cable Cubby AC Power Module”.


The unit is not UL Listed if it uses any AC power
module other than Model “Cable Cubby AC Power
Module”.

NOTE:

For models that do not include a power module,

see the Extron website to select a power module that is
suitable for your location.

The power module takes up two or three AAP spaces, depending on
the model, and may be installed before or after the AAP assembly is installed. It may be installed with AAPs on either side.

1.

Secure the power module into position with #4-40 Phillips head screws and star washers.

CAUTION:

Risk of electric shock: To ensure proper electrical grounding, use the provided grounding screws and star

washers.

ATTENTION:

Risque de choc électrique: Afin d’assurer une mise à la terre correcte, utilisez les fixations de mise à la

terre et les rondelles en étoile fournies.

2.

Run the cable or conduit to a convenient junction box. Extron recommends the circuit be attached to a junction box that is
directly wired to the main circuit.

Step 6 — AAP Assembly

Install all desired cables into the cable pass-through AAPs and
install the AAPs into the cable cubby.
The simplest way to install the cables and AAPs is to populate
the AAP brackets outside the cubby and then install the
populated AAP shelf assembly into the cubby.
Install cables in the pass-through holes as shown in the figure
to the right.

TIP:

Hand tightening the #4-40 nuts makes it easier to

place and secure the assembly inside the enclosure.

NOTE:

An extra column of AAP bracket mounting points is

available for use with TLP Single-space AAP mounting
brackets. Single-space brackets will not fit in any other
location.

Rear Brackets

Front Brackets

Secure the power module

to the TLP Pro 720C frame

with #4-40 Phillips head

screws and star washers.

Extr

on

The extra column

of mounting points

is for installing

single-space

AAP brackets.

Advertising