PS 124 12 VDC, 4 Amp Power Supply • Installation Manual

PS 124, cont’d

4

Connections

Input power — using the IEC power cord

Use the included IEC power cord to connect the PS 124 to a

100 VAC to 240 VAC, 50-60 Hz power source.

W

The circuit breaker used for this connection should

be rated 20 amps maximum.

Input power — using the Flexible Conduit Adapter

Kit

The optional Flexible Conduit Adapter Kit, part # 70-228-02,

provides a convenient means to replace the IEC power cord with

conduit when required by local codes.
The kit consists of:
• One EMT adaptor plate
• One 6-foot long electrical conduit
• Three 7.5 feet, 18-gauge spade connector power wires
• One UL Listed zip tie wrap
• Three auxiliary crimp style spade connectors designed for

14- to 16-gauge wires

N

Extron recommends using a crimp tool such as Molex

part #19285-0008 to terminate the spade connectors.

Make certain the PS 124 and all connected devices are turned off

and disconnected from the power source before beginning.

W

The circuit breaker used for this connection should

be rated 20 amps maximum.

W

For permanently connected equipment there

must be a readily accessible disconnect device

incorporated in the building installation wiring.

W

Installation and service must be performed by a

qualified electrician only.