X2*
= Power save mode/state:
0 = auto power save and standby power mode off (power save off) (default)
1 = set auto power save timer running, but not triggered
2 = force auto power save on
3 = force standby power save on
4 = force network standby power save on (turn off network switch)
X2(
= Temperature in °C. The response is 3 digits with leading zeros
X3)
= Relay status (VLR 102 response)
0 = Off
1 = On
X3!
= Contact closure input state (VLR 102 response)
0 = Open
1 = Closed
X3@
= On/off status: 0 = off/disable; 1 = on/enable
X3#
= Audio output volume: 000 to 100, default 80
X3$
= Version number (listed to two decimal places, e.g. x.xx).
X3%
= Input audio gain and attenuation: ‑18 to +24 dB V, in 1 dB steps.
X3^
= PVT SW HDMI RGB D inputs 2 and 4 only
2 = input 2
4 = input 4
X3&
= Pixel phase ‑ 0‑63 (32 = default)
X3*
= Horizontal start ‑ 0‑255 (128 = default)
X3(
= Vertical start ‑ 0‑255 (128 = default)