SMX System MultiMatrix Switcher • SIS Configuration and Control

54

X6#

= Verbose mode

0

= clear/none

(default for Telnet connections)

1

= verbose mode (default for RS-232

and RS-422 connections)

2

= tagged responses for queries

3

= verbose mode and tagged for

queries

X6^

= Baud rate

9600 (default), 9200, 38400, 115200

X6&

= Parity

O

= odd

E

= even

N

= none

M

= mark

S

= space

X6*

= Data bits

7

,

8

X6(

= Stop bits

1

,

2

X7)

= Port type

0

= RS-232 (default)

1

= RS-422

2

= RS-485

X7#

= Web page priority flag

0

= internal (default factory reset)

1

= user

X7$

= Password

12 digits, alphanumeric
User or admin

NOTES:

•

The following characters are invalid or not recommended in the name:

~ , @ = '

[ ] { } < > ` " ; : | \ ?

and

space

•

User password cannot be assigned if no admin password exists (returns error code

E14

). When admin password is cleared, then user and all security level passwords

are deleted.

X7%

= Daylight Saving Time

0

= Daylight Saving Time off or ignore

1

= Daylight Saving Time on

(USA - April to October)

2

= Daylight Saving Time on

(Europe - March to October)

3

= Daylight Saving Time on

(Brazil - October to March)

X7^

= Event number

0

-

99

Event must be running.

X7&

= Event data size

b

= bit

B

= byte (8 bits)

S

= short (16 bits)

L

= long (32 bits)

NOTE: The parameter is case sensitive and may be optionally preceded by

A

(And) or

O

(Or) to logically combine with content instead of replacing it.

X7(

= Number of bytes to read

1

-

127

X8)

= E-mail event number or mailbox

1

-

64

Response is 3 digits with leading zeros.

X8!

= E-mail recipient address