Cal9 8rw, Cal9 8rw ffl, 9” cal lensed cylinders, wet location – Gotham 9 CAL Lensed Cylinders, Wet Location SpecSheet User Manual

Page 3

Advertising
background image

GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com

PAGE 3 OF 3

CAL-9-LEnsEd

© 2006-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 12/05/13. specifications subject to change without notice.

CAL9 8RW

200W A23 LAMP, 3800 RATED LUMENS, 1.2 S/MH, TEST NO. LTL14201

CAL9 8RW FFL

200W A23 LAMP, 3800 RATED LUMENS, 1.3 S/MH, TEST NO. LTL14202

PH

OTO
M

ET

RY

Distribution Curve

Distribution Data

Output Data

Coefficient of Utilization

Illuminance: Single Luminaire 30” Above Floor

9” CAL

Lensed Cylinders, Wet Location

A21 or A23 Lamp, 8” Aperture

Zone

Lumens % Lamp

0° - 30°
0° - 40°
0° - 60°
0° - 90°

90° - 180°

0° - 180°

867.8

1382.6
1989.7
2163.2

0.0

2163.2

22.8
36.4
52.4
56.9

0.0

*56.9

*E fficiency

10°

20°

30°

40°

50°

60°

70°

80°

90°

0

200

400

600

800

1000

pf
pc
pw

20%

80%

70%

50%

50% 30% 50% 30% 50% 30%

1
2
3
4
5
6
7
8
9

10

.61
.55
.50
.45
.41
.37
.34
.31
.29
.27

.59
.52
.46
.41
.36
.33
.30
.27
.25
.23

.60
.54
.49
.44
.40
.37
.34
.31
.29
.27

.58
.51
.45
.40
.36
.33
.30
.27
.25
.23

.58
.52
.47
.43
.39
.36
.33
.30
.28
.26

.56
.50
.44
.39
.35
.32
.29
.27
.24
.23

F rom 0°

Ave

Lumens

0
5

15
25
35
45
55
65
75
85
90

1158
1152
1073

990
837
504
238
112

44
11

0

109
303
456
515
389
218
113

49
12

50% beam angle

62.0°

10% beam angle

96.9°

Mount
height

Inital fc

at beam

center

B eam

diameter

fc at

beam

edge

B eam

diameter

fc at

beam

edge

8

10
12
14
16

38.3
20.6
12.8

8.8
6.4

6.6
9.0

11.4
13.8
16.2

19.1
10.3

6.4
4.4
3.2

12.4
16.9
21.4
25.9
30.4

3.8
2.1
1.3
0.9
0.6

Zone

Lumens % Lamp

0° - 30°
0° - 40°
0° - 60°
0° - 90°

90° - 180°

0° - 180°

1016.2
1548.0
2114.8
2305.9

0.0

2305.9

26.7
40.7
55.7
60.7

0.0

*60.7

*E fficiency

10°

20°

30°

40°

50°

60°

70°

80°

90°

0

200

400

600

800

1000

1200

pf
pc
pw

20%

80%

70%

50%

50% 30% 50% 30% 50% 30%

1
2
3
4
5
6
7
8
9

10

.65
.59
.53
.48
.44
.40
.37
.34
.32
.29

.63
.56
.49
.44
.39
.36
.32
.30
.27
.25

.64
.58
.52
.47
.43
.40
.37
.34
.31
.29

.62
.55
.49
.43
.39
.35
.32
.29
.27
.25

.61
.56
.51
.46
.42
.39
.36
.33
.31
.29

.60
.53
.47
.42
.38
.35
.32
.29
.27
.25

F rom 0°

Ave

Lumens

0
5

15
25
35
45
55
65
75
85
90

1166
1170
1253
1208

864
432
249
127

46
11

0

113
354
549
532
343
224
127

51
13

50% beam angle

65.3°

10% beam angle

94.8°

Mount
height

Inital fc

at beam

center

B eam

diameter

fc at

beam

edge

B eam

diameter

fc at

beam

edge

8

10
12
14
16

38.5
20.7
12.9

8.8
6.4

7.0
9.6

12.2
14.7
17.3

19.3
10.4

6.5
4.4
3.2

12.0
16.3
20.7
25.0
29.3

3.9
2.1
1.3
0.9
0.6

PHOTOMETRY NOTES

Tested to current IES and NEMA standards under stabilized laboratory conditions.

Actual performance may differ as a result of end-user environment and application.

Consult factory or IES file for microgroove baffle, black cone or other photometric reports.

Advertising